Страница 2: ...VigorAccess User Installation Guide 2 History Table Date Descriptions Version By 2005 7 22 Initial V1 0 Jenny Jimmy Amy...

Страница 3: ...L 4 Copyright 5 DrayTek Limited Warranty 6 Be a Registered Owner 7 Caution 7 Safety Instructions 8 European Community Declarations 9 Customer Support 10 Organization 11 CHAPTER 1 PREFACE AND HARDWARE...

Страница 4: ...one of the series of high performance IP DSLAM The information contained in this document is subject to change without notice If you have any inquiries please feel free to contact our support team via...

Страница 5: ...lated into any language without written permission from the copyright holders Trademark DrayTek is a registered trademark of DrayTek Corp IP DSLAM product series are trademarks of DrayTek Corp Other t...

Страница 6: ...ging for either parts or labor to whatever extent we deem necessarily to restore the product in proper operating condition Any replacement will consist of a new or remanufactured functionally equivale...

Страница 7: ...ely fill in the registration card and mail it to the address found on the reverse side of the card Registered owners will receive our future product and update information CAUTION There is the risk of...

Страница 8: ...ng the device on chassis to maintain air circulation and stable condition is recommended Do not work alone if the operation environment is dangerous Check and avoid the potential hazard for moist envi...

Страница 9: ...User Installation Guide 9 EUROPEAN COMMUNITY DECLARATIONS DrayTek Corporation declares that the IP DSLAM is in compliance with the essential requirements and other relevant provisions of R TTE Direct...

Страница 10: ...oduct model and serial number Warranty information Date that you received IP DSLAM Product configuration Software release version number Brief description of your problem Steps that you may take to so...

Страница 11: ...ace and Hardware Description Provides a product overview and hardware architecture description 12 2 Installation Provides installation LED indication and hardware installation 31 3 IPDSLAM Product Fea...

Страница 12: ...equipped with 24 ADSL2 ports is designed for ISP Internet Service Provider to implement bandwidth management for multiple subscribers As IP DSLAM supports high upstream and downstream bit rates perfor...

Страница 13: ...gaming service Stream TV Service IP DSLAM uses ADSL 2 high speed DSL technology and supports stream TV Service Video on Demand Service Service provider can offer multimedia services by setting up vide...

Страница 14: ...th load balance feature By combining VoIP devices system integrator provides multiple services with VoIP Video on Demand and ADSL2 bundle solution The firewall and VPN security of VoIP security router...

Страница 15: ...agement with RJ45 Gigabits optical interface with SC connector GE subtend interface with RJ45 connector ADSL2 with RJ21 connector and POTS with RJ21 connector Users can connect the IP DSLAM slave to a...

Страница 16: ...pose of master unit is as a central unit in DSL application to manage all slave units connected with it Master unit always collects related information from slave units Moreover users can manage slave...

Страница 17: ...deployments Management Single IP Management Q o S Packet filter and classification 1 2 3 Slave Overview The role of slave unit is to provide a high performance good services DSL feature in Internet en...

Страница 18: ...ch racks are shown in Figure 1 6 Figure 1 6 Brackets for 19 23 inch rack Attach the brackets to the chassis in 19 23 inch rack as shown in Figure 1 7 The second bracket attaches the other side of the...

Страница 19: ...arily rubbing on desk 1 3 3 Power Ground Connections on the Rear Panel The AC input and ground connections are on the rear panel and shown in Figure 1 8 You can connect the rack to ground by spring sc...

Страница 20: ...sis ground to stud terminal labeled FG Step 4 Connect the power lead from the positive terminal of power source to the stud terminal labeled RTN Warning The Figure 1 10 shows the DC power supply termi...

Страница 21: ...MDF on building or CO side in Figure 1 11 An MDF is usually place in the building s telephony room or on central office room It can terminate the outside telephone line into the building Most MDF has...

Страница 22: ...or telephone room The CPP is the point of termination for the outside telephone company lines coming into a building and the telephone lines in the building Figure 1 12 CPP front panels The following...

Страница 23: ...Installation CPP Scenario B Phone service is available in IP DSLAM You can connect a RJ 11 jack port attached in a CPP to a telephone directly or applied in the same way shared in ADSL modem The Data...

Страница 24: ...as shown in Figure 1 15 converts the RJ45 to the RS232 interface The RJ45 jet connects to a console interface in the IP DSLAM while the RS232 DB9 connecting to a console port on the computer The defa...

Страница 25: ...either straight or crossover RJ45 cables These cables are used on UP1 UP2 MGN interfaces Figure 1 16 Applicable on both straight through and crossover RJ45 cables overview RJ 45 Straight through Cabl...

Страница 26: ...n Master and UP1 UP2 MGN port on Slave Figure 1 17 Applicable on both straight through and crossover RJ45 8C8P1 cable 1 8C8P means the Ethernet cable with 8 wires connector in 1000M Ethernet physical...

Страница 27: ...ingle mode will be harmful when operate especially to the eyes During normal operation with cable connection this energy is confined to the cable with no danger present Because the laser radiation is...

Страница 28: ...onnections are made with two 50 pin champ cables Figure 1 19 that are attached to the RJ21 interface on IP DSLAM Each cable terminates with a 50 pin Telco straight champ connector Refer to Table1 2 fo...

Страница 29: ...RING 9 46 21 Violet blue Blue violet TIP RING 21 35 10 Red gray Gray red TIP RING 10 47 22 Violet orange Orange violet TIP RING 22 36 11 Black blue Blue black TIP RING 11 48 23 Violet green Green vio...

Страница 30: ...or the Alarm Relay connector pin Signal Description 1 NC1 NORMAL CLOSE CONTACT GROUP1 2 COM1 COMMON CONTACT GROUP1 3 NO1 NORMAL OPEN CONTACT GROUP1 4 NOT USED 5 NOT USED 6 NC2 NORMAL CLOSE CONTACT GRO...

Страница 31: ...ction 2 1 System Connection Description Section 2 2 IP DSLAM Master Setup Section 2 3 IP DSLAM Slave Setup 2 1 System Connection Description There are following steps to setup the IP DSLAM connection...

Страница 32: ...anel Connection All connections are made on the front panel of the IP DSLAM except power connector The connections on the front panel of the IP DSLAM are shown in Figure 2 2 There are interfaces on Ma...

Страница 33: ...CLI command UPLINK The uplink interface with SC connector should be long haul or short haul Gigabits optical connection Subtend The subtend interface with RJ45 interface is Gigabit Ethernet connection...

Страница 34: ...5 Blue PC Ethernet Interface Gx RJ 45 8P8C Blue Connect to slave unit UP1 PHONE RJ 21 MDF or Panel to PSTN LINE RJ 21 To subscriber copper line 2 2 2 Master Console Port Connection For the initial con...

Страница 35: ...n Users can connect the RJ 45 cable to the Ethernet port of the computer The IP address is 172 16 1 1 by default The subnet of PC should be the same as default IP setting Admin network outband OUTBAND...

Страница 36: ...s can connect the uplink of IPDSLAM Slave to subtend interface of IPDSLAM Master by plug and play Admin dsl m Press exit to return Entering character mode Escape character is dsl master or Admin dsl s...

Страница 37: ...VigorAccess User Installation Guide 37 Figure 2 5 Master subtend connection...

Страница 38: ...connection and power on the units users can inspect the LED on the front panel The Master is consisted of two parts of features One is controller for alarm subtend and optical feature The others are D...

Страница 39: ...links during data transmitting receiving LNK OFF OFF means No Ethernet link established Green The speed for Ethernet is 1000Mbps when LNK LED is ON 1000 OFF The speed for Ethernet is 10 100Mbps when L...

Страница 40: ...will reboot to factory default configuration Console A RS232 serial interface is used to connect a local management computer UPLINK UP1 UP2 MGN Support two 10 100M or one 1000M Ethernet ports to Inter...

Страница 41: ...le port Users can connect the RJ 45 end of the console cable to the console port of the network module On the other side users can connect the other end to serial ports of a computer help Command Desc...

Страница 42: ...ry memset Memset upgrade Upgrade upload Upload a file on to the Device wizard A shortcut Type wizard for help Figure 2 8 IP DSLAM slave console port connection 2 3 3 Slave Management Port Connection T...

Страница 43: ...on 1 5 2 3 5 Slave LED Indication After complete the interface installation users can complete the connections by only 4 steps First connect the power cord in the rear part of IP DSLAM to AC inlet or...

Страница 44: ...ed for Ethernet is 100M when LNK LED is ON 100 OFF The speed for Ethernet is 10M when LNK LED is ON Green The transmitted mode for Ethernet is in full duplex mode when LNK LED is ON UP1 UP2 MGN FDX OF...

Страница 45: ...combination forms are integrated solution for providing broadband services to multiple tenants such as apartments hotels offices and campus buildings IP DSLAM supports a lot of features as listed bel...

Страница 46: ...094 VLAN identifications IEEE 802 1p Priority IP DSLAM supports IEEE 802 1p to assign priority levels to all individual ports Users can set different quality of service for individual application For...

Страница 47: ...ries in Ethernet uplink port Multi Protocol Encapsulation IP DSLAM supports multi protocol encapsulation over ATM adaptation Layer 5 based on RFC2684 Management IP DSLAM supports some management metho...

Страница 48: ...ridging IP DSLAM supports for multiple queues per port There are different queues both on ATM and Ethernet uplink Four queues supported per ATM port Eight queues supported per physical Ethernet port 3...

Страница 49: ...based on a per ingress bridge port 1 Using Source Port configuration for untagged packets 2 Using Classifier actions 3 Using priority regeneration table mapping ingress priority to egress priority 4 C...

Страница 50: ...om one port to another port 3 3 4 MAC Address Tracking IP DSLAM can be configured to track a global list of MAC addresses When these MAC addresses move from one port to another port a trap is generate...

Страница 51: ...e by another sequence in one step Moreover IP DSLAM also supports for capturing unicast and multicast packets that fail lookup in the forwarding database is provided Users may write their own applicat...

Страница 52: ...ent 3 5 2 Diagnostic Testing IP DSLAM supports OAM I 610 end to end and segment loop back and DELT 3 5 3 Dynamic Modification IP DSLAM supports a lot of dynamic modifications and is shown as below VPI...

Страница 53: ...two Ethernet uplinks of IP DSLAM can be used in an active stand by mode for data and management path with a provision to fall back to standby link in the event of the active links failure Redundancy R...

Страница 54: ...telnet on the IP DSLAM Controller and use the following two ways One is console interface another is telnet by management port The IP DSLAM Controller console interface will connect to PC console port...

Страница 55: ...IP address without VLAN Admin network inband IP_addr NetMask Edit the inband IP address with VLAN Admin network inband IP_addr NetMask vlan_id 4 1 1 2 Outband IP Address Users can use the following co...

Страница 56: ...0 0 0 0 Add a static route entry Admin network route a TargetIP NetMask GatewayIP Edit the static route entry Admin network route e RtIdx TargetIP NetMask GatewayIP Delete the static route entry Admin...

Страница 57: ...he following commands to configure the SNMP settings including SNMP community SNMP Trap port and SNMP Trap host Let the EMS can communicate with IP DSLAM via SNMP Enter service directory Admin service...

Страница 58: ...following command to save the current configuration Admin commit 4 1 6 Enable Disable the Port Users can use the following commands to enable or disable the port on Controller By default G1 to G6 are...

Страница 59: ...the following command to check the status of DSL The commands are listed as below get adsl atuc physical ifname dsl for downstream get adsl atur physical ifname dsl for upstream 0 23 4 2 2 How to Enab...

Страница 60: ...ow to Change ADSL to Fast Channel Rate Commands are shown as below modify adsl line intf ifname dsl disable modify adsl line profile ifname dsl type fastOnly atucfastmaxtxrate 0x7e0000 modify adsl lin...

Страница 61: ...ame aggr 0 ip new ip mask new mask or Non Aggregarion Ethernet modify ethernet intf ifname eth ip new ip mask new mask 1 or 2 4 3 2 How to Create more VC EOA Bridge Commands are shown as below create...

Страница 62: ...d other source addresses from bridge port bridge port id are denied 4 3 7 How to deny MAC address globally Commands are shown as below create acl global macentry macaddr 00 00 00 01 02 03 deny enable...

Страница 63: ...id enable get stp port info portid bridge port id 4 3 10 How to enable IGMP Snooping Commands are shown as below NOTE IGMP Snooping is Factory Default Setting create filter rule entry ruleid id actio...

Страница 64: ...ug 23 16 52 58 2004 81160 RO active remove fname nvram bin control CP bin gz version 1 depends on real status download src CP bin gz dest nvram bin control CP bin gz ip server ip list Name Ver Time Si...

Страница 65: ...hernet intf ifname eth 0 ip ip_address mask mask download src TEImage bin gz dest nvram TEImage bin ip server_ip Downloading the File Download file size is 1991180 Check if TEImage bin shall uncompres...

Страница 66: ...how pvc create dsl 1 24 vc 1 8 vpi vci llcmux vcmux interleaved fast pvc delete dsl 1 24 vc 1 8 bridge delete bridge id 1 193 tca show acked critical show acked firmware upgrade source file CP DP FD D...