Draper Ultimate Access Series Скачать руководство пользователя страница 1

Installation/Operating Instructions

220V Ultimate Access Electric Projection Screen by Draper

Copyright © 2009 Draper Inc. 

Form UltimateAccess220V_Inst09-R 

Printed in U.S.A.

Hanging Screen 

When locating viewing surface and checking clear ance for screen’s op er a tion, 
remember surface is centered in the length of the case.
Screen is normally recessed above ceiling and may be installed in a variety 
of ways. See typical installations detailed on page 3. Re gard less of mount ing 
method used, the following points apply:

  Mounting brackets are packed separately in carton. Engage each 

 

bracket with top of housing as shown below and tighten set screws. A 

 

bracket should be within 46 cm from each end of screen case. Brackets 

 

can be removed and case mounted with lag screws through top of case 

 

(holes drilled on site).

  Screen should be positively and securely supported so that vibration or 

 

even abusive pulling on viewing surface will not weaken in stal la tion.

  Installer must insure that fasteners used are of adequate strength and 

 

suitable for the mounting surface chosen. 

  Entire bottom of case must be readily accessible after in stal la tion is 

 complete.

  The bottom access panel, trap door, and lower edge of the case are 

 

joined with continuous hinge joints and must operate freely. Front and 

 

back of case must be straight–not forced to warp or bow. Hinge joints 

Caution

 Read in 

struc tions through com plete ly before pro ceed ing.

  Follow instructions carefully. Installation con trary to in struc tions 

 invalidates 

warranty.

  Entire bottom of screen case should be unobstructed to permit 

 

access to bottom panel for electrical connections or servicing.

  Screen should be installed level (using a carpenter’s level).

  Nothing should be fastened to screen dowel or viewing surface.

  Operating switch(es) and mounting brackets are packed sep a rate ly 

 

in screen car ton. Do not discard with packing material.

  Screen operates on 220 V AC, 50 Hz. current.

NOTE: 

Screen has been thoroughly inspected and tested at fac to ry and 

found to be operating properly prior to shipment.

Electrical Con nec tions

Screen operates on 220 V AC, 50 Hz. cur rent.
Junc tion box is lo cat ed just above the bottom access panel at left end of 
screen. 
Open the access panel/trap door for access to the junction box cover. (See 
bottom access panel/trap door opening and closing instructions below). 
Remove two (2) hex head screws that secure the cover to the junction box to 
expose the terminal strip per wiring diagram on page 4.
If optional low voltage control or video interface control is specifi ed and factory 
installed, please refer to wiring diagram on page 4.
Screen is shipped with internal wiring complete and control switch(es) fully 
boxed. Wire to connect screen to switch(es) and switch(es) to power supply 
should be furnished by installer. Con nec tions should be made in ac cor dance 
with attached wiring diagram, and wiring should comply with national and 
local electrical codes.
All operating switches should be “off” before power is connected.

These Installation/Operating Instructions are available in the offi cial language 
of the country where you purchase the product. Please contact your distributor 
to request a copy.
Vous pourriez demander les instructions d’installation et d’opération traduises 
dans la langue offi cielle du pays ou vous achetez le produit. Veuillez 
demander à votre distributeur.
Die Gebrauchsanweisung für Installation und Konstruktion sind in der 
offi ziellen Sprache des Landes, indem Sie das Produkt gekauft haben, 
vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.

If you encounter any diffi culties installing or ser vic ing your Ultimate Access screen, call 
your dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-1689.

 

 

 

®

Bottom Access Panel/Trap Door Opening & Closing

After screen case has been mounted, remove the dowel shipping brackets 
from dowel if provided. 

A spring latch at each end of the trap door holds 

this assembly closed. In some screens there will also be a spring latch 
near the center of the case. 

To gain access to inside of screen case, disen-

gage spring latch at each end of the case (and near the center of the case, if 
applicable) by sliding the latch lever towards the center of screen case, then 
pull down slightly on the trap door assembly. The latch levers are somewhat 
concealed from view. Locate these with the trap door open by feeling for the 
vertical latch lever above the door about 8 cm from case endcaps and near 
the center of the case.
The assembly will swing down, opening about 135°. Pivot the prop arms at 
each end of the trap door assembly towards the ends of screen case. Prop 
arms engage with a hole in each endcap to hold the trap door assembly fully 
open. To close the trap door assembly disengage prop arms from endcaps 
and pivot these over the access panel. Swing the trap door as sem bly upward, 
stopping just before the latch levers hit the bottom fl anges of the endcaps 
(and center of case where appropriate). Pull levers of latches towards center 
of screen case to allow the trap door assembly to be pivoted to its closed po-
sition. Make sure that the spring latch levers engage fully with case endcaps 
(and center of case where appropriate).

Typical Installation

Alternate 
Installation
(additional 
set of brack-
ets required 
but not in-
cluded)

Slots along top of case permit 
brackets to be set at an angle

Case dimensions 
on page 4.

Dowel

Shipping
Bracket

Remove shipping brackets 
before operating screen.

 

must be free of mastic or paint build up, and trapdoor and access panel 

 

must be unobstructed by ceiling tiles.

  If case is painted on location, removal of roller/fabric assembly is 

 

recommended prior to painting. If not removed, slots on bottom of case 

 

should be shield ed to protect view ing surface from paint splatters or 

 overspray.

➆ 

Do not seal unit in ceiling until elec tri cal con nec tions have been made 

 

and screen has been op er at ed successfully.