Draper Salara Скачать руководство пользователя страница 1

Installation Instructions

220V IR Plug & Play Salara by Draper

Copyright ©2007 Draper Inc.  Form Salara-IRPlug&Play-220V_Inst07  Printed in U.S.A.

Wall/Ceiling Flush Mounting

 Attach Mounting Brackets to wall or ceiling (see Fig. 1). The installer should 

  furnish screws, toggle bolts, molly bolts, nylon or lead anchors as required 
  by the mounting surface. Installer also needs to ensure the mounting 
  surface is reinforced suffi ciently to support the screen. 

Brackets must be 

  level with each other.

Figure 1

Caution

 Read instructions through completely before proceeding.

 Follow instructions carefully. Installation con trary to instructions in val i-

 dates warranty.

 Screen should be accessible for complete removal should fabric

become damaged or should other ser vice be required.

 Screen should be installed level (using a carpenter’s level).

 Nothing should be fastened to screen dowel or viewing surface.

 Operating switch (es) packed separately in screen carton. Do not 

discard with packing material.

 Screen operates on 220V AC, 50 Hz., 1 ph. current.

NOTE

: Screen has been thoroughly inspected and tested at factory and 

found to be operating properly prior to shipment.

 

 

 

 

If you encounter any diffi culty installing or ser vic ing your Salara, call your dealer 
or Draper, Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-7142.

Dimensional drawings on page 2

Wall

Mounting

Bracket

1

1

/

2

"

 Plug the power cord (included if ordered) into the motor end of the screen 

  case (left end as the viewer sees the screen).

  Attach the screen by snapping the extrusions on the back of the case onto 

  the brackets. With the lower edge of the screen case tilted away from the 
  wall, engage the rib on top of the case with the slot on each bracket. Slide 
  the screen case along the brackets to adjust the screen location from left to 
  right if necessary (see Fig. 2). Once the case is in position, pivot the case 
  back toward the brackets until the lower edge of the case "snaps" into place 
  with the spring-loaded latch (see Fig. 3).

Operation

Screen is equipped with a handheld remote or 3-position operating switch 
(see below). Three positions (up-off-down) per mit operation to be stopped at 
any point. Factory adjusted limit switches au to mat i cal ly stop screen when fully 
down or fully up.

Wiring/Control Options:

Plug & Play

TM

 

Provided with built-in IR receiver, handheld IR remote 

control transmitter and 10' (3m) IEC cordset. No wiring necessary except to 
connect to RS232.

Electrical Connections

Screen operates on 220V AC, 50 Hz., 1 ph. current. Screen shipped with 
internal wiring complete. Junction box is located inside left endcap and cover 
plate is secured to endcap with one screw. Screen is shipped with internal 
wiring complete and control switch(es) fully boxed. No external wiring is 
needed. unless connecting to RS232. Plug cord into standard 220V AC outlet.

All operating switches should be “OFF” before power is connected.

 

These Installation/Operating Instructions are available in the offi cial 

language of the country where you purchase the product. Please contact your 
distributor to request a copy.
 

Vous pourriez demander les instructions d’installation et d’opération 

traduises dans la langue offi cielle du pays ou vous achetez le produit. Veuillez 
demander à votre distributeur.
 

Die Gebrauchsanweisung für Installation und Konstruktion sind in 

der offi ziellen Sprache des Landes, indem Sie das Produkt gekauft haben, 
vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.

Figure 3

Extrusions along
back of case

1

2

3

Figure 2

Mounting

Bracket

1

1

/

2

"

Ceiling

Adjustments

  Screen has been factory set and should not normally require further 
adjustment. If you desire to change the “up” and “down” stopping positions, 
follow the procedures below.
There are two holes in the left end cap (as seen from audience) for both limit 
switch adjustments and neither is labled. The hole closest to the audience is 
the up limit and the hole furthest from the audience is the down limit

“Down” limit switch: 

Down stopping position can be adjusted by turning 

knob furthest from audience with a screw driver or hex wrench. Turning knob 
counterclockwise will allow viewing surface to run farther down. Turning it 
clockwise will reduce the amount of exposed viewing surface. 

“Up” limit switch: You should never have to adjust this limit! 

If you do, 

however, the Up stopping position can be adjusted by turning knob closest 
to audience with a screw driver or hex wrench through the small grommet. 
Turning knob counterclockwise will allow surface to run farther into screen 
case. Turning it clockwise will allow viewing surface to stop farther out of 
screen case.

CAUTION: 

Be sure all switches are in “off” position before adjusting limit 

switches. Always be prepared to shut screen off manually when new 
adjustment is being tested. Screen may be severely damaged if viewing 
surface is allowed to run too far up or too far down.