Installation Instructions

110-120V Salara/Hardwire by Draper

Copyright ©2015 Draper Inc.  Form Salara-HW_Inst15  Printed in U.S.A.

Wall/Ceiling Flush Mounting

1

 Attach Mounting Brackets to wall or ceiling (see Fig. 1). The installer should  

  furnish screws, toggle bolts, molly bolts, nylon or lead anchors as required  

  by the mounting surface. Installer also needs to ensure the mounting  

  surface is reinforced sufficiently to support the screen. 

Brackets must be  

  level with each other.

Figure 1

Caution

1

 Read instructions through completely before proceeding.

2

 Follow instructions carefully. Installation contrary to instructions invali-

dates warranty.

3

 Screen should be accessible for complete removal should fabric 

become damaged or should other service be required.

4

 Screen should be installed level (using a carpenter’s level).

5

 Nothing should be fastened to screen dowel or viewing surface.

6

 Operating switch(es) packed separately in screen carton. Do not  

discard with packing material.

7

 Screen operates on 110-120V, 60 hz., 1.1 amp current draw.

NOTE

: Screen has been thoroughly inspected and tested at factory and  

found to be operating properly prior to shipment.

 

 

 

 

Figure 3

If you encounter any difficulty installing or servicing your Salara, call your dealer 
or Draper, Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-7142.

Dimensional drawings on page 2

Wall

Mounting

Bracket

1

1

/

2

"

2

 Attach the screen by snapping the extrusions on the back of the case onto  

  the brackets. With the lower edge of the screen case tilted away from the  

  wall, engage the rib on top of the case with the slot on each bracket. Slide  

  the screen case along the brackets to adjust the screen location from left to  

  right if necessary (see Fig. 2). Once the case is in position, pivot the case  

  back toward the brackets until the lower edge of the case "snaps" into place  

  with the spring-loaded latch (see Fig. 3).

Operation

  Screen is equipped with a handheld remote or 3-position operating switch 

(see below). Three positions (up-off-down) permit operation to be stopped at 

any point. Factory adjusted limit switches automatically stop screen when fully 

down or fully up.

Wiring/Control Options:

Salara/Hardwire—

Provided with 3-position wall switch for 110-120V AC. 

Controls for 110-120V AC hardwired Salara:

110-120V Single Station Control —

 3-position up-off-down switch permits 

operation to be stopped at any point. Factory adjusted limit switches auto-

matically stop screen when fully down or fully up.

110-120V Multiple Station Control

—Switches are similar in appearance to 

110V Single Station Control. Screen stops when switch is released and  may 

be restarted in either direction. Factory adjusted limit switches stop screen 

automatically when fully down or fully up.

24V Control —

 Three-button up-stop-down switches stop at any point de-

sired, operate in any sequence. Factory adjusted limit switches automatically 

stop screen when fully down or fully up.

Key Operated Switching — 

Two kinds of key-operated switches are 

optionally available with this unit. 

  The key-operated power supply switch controls power to the screen and  

    switches. When it is “off”, the switches will not operate screen. Key may be  

    removed from the switch in either “on” or “off” position. 

2

  A three-position key switch permits the screen to be operated directly by  

    key. In this case, the screen’s operator must always have a key.

RS232/Ethernet—

Serial communication and network communication 

optionally available with wall switches, RF or IR remote.

Salara/Hardwire with Built-in IR

—Provided with handheld infrared remote 

transmitter.

Electrical Connections

  Screen operates on 110-120V AC, 1.1 amp current draw. Duty cycle: On 

Adjustments

Please Note: Screen limits are factory set for optimum performance of 

the screen. A procedure is outlined below for minor tweaks, but any 

adjustment of these limits may negatively affect the flatness of the 

screen surface and could also void the warranty. Please check with 

Draper prior to resetting screen limits.

CAUTION: Always be prepared to shut screen off manually when new 

adjustment is being tested. Screen may be severely damaged if viewing 

surface is allowed to run too far up or too far down.

C

AUTION: Be sure all switches are in “off” position before adjusting 

limit switches.

Standard or IR Hardwired Salara

There are two holes in the left end cap (as seen from audience) for both limit 

switch adjustments and neither is labled. The hole closest to the audience is 

the up limit and the hole furthest from the audience is the down limit

“Down” limit switch: 

Down stopping position can be adjusted by turning 

knob furthest from audience with a screw driver or hex wrench. Turning knob 

counterclockwise will allow viewing surface to run farther down. Turning it 

clockwise will reduce the amount of exposed viewing surface. 

“Up” limit switch: You should never have to adjust this limit! 

If you do, 

however, the Up stopping position can be adjusted by turning knob closest 

to audience with a screw driver or hex wrench through the small grommet. 

Turning knob counterclockwise will allow surface to run farther into the screen 

case. Turning it clockwise will allow viewing surface to stop farther out of the 

screen case.

1

2

3

Figure 2

26 seconds/Off 3 minutes. Screen shipped with internal wiring complete. 

Junction box is located inside left endcap and cover plate is secured to 

endcap with one screw. Junction box contains red, black and white pigtail 

leads and green internal ground wire, per wiring diagram on reverse.

  Screen is shipped with internal wiring complete and control switch(es) fully 

boxed. Wire connecting screen to switch(es) and switch(es) to power supply 

should be furnished by installer. Connections should be made in accordance 

with attached wiring diagram, and wiring should comply with National and 

local electrical codes. When connections are complete, test screen operation. 

The switch cover plate is not labeled "Up" and "Down." If screen operates 

in the opposite direction of the switch button (i.e. pressing switch up makes 

the screen go down), no re-wiring is necessary; simply flip the switch 180 

degrees.

All operating switches should be “OFF” before power is connected.

Mounting

Bracket

1

1

/

2

"

Ceiling

Extrusions along

back of case

US Patent 

Pending.

These instructions are meant as a guide only. They do not imply any 

responsibility on the part of Draper, Inc. for improper installation or faulty 

workmanship at the jobsite.