Draper Paragon V Series Скачать руководство пользователя страница 1

Caution

 1

  Read instructions through completely before proceeding.

 2

  Follow instructions carefully. Installation contrary to instructions invalidates  

   warranty.

 3

  Pick up screen case from 

ends only

. Picking case up at other points 

will  

    damage case 

and 

may damage fabric

.

 4

  To insure a safe installation, the 

entire weight

 of the unit MUST BE  

   

supported by the end-plates.

 5

  Entire bottom of screen case should be unobstructed to permit access to  

   

bottom panel for making electrical connections or servicing.

 6

  Screen should be installed level (using a carpenter’s level).

 7

  Operating switch(es) packed separately in screen carton. Do not discard  

   

with packing material.

 8

 

Screen operates on 220V AC, 50 Hz., 1ph. current.

  NOTE

: Screen has been thoroughly inspected and tested at factory and found to  

  be operating properly prior to shipment.

Mounting Screen

Regardless of mounting method used, the following points apply:

1

  Screen should be lifted into position 

only by the end mounting brackets.  

  Keep case level by lifting end plates simultaneously to prevent surface  

  damage. Draper provides eyebolts to use in hoisting the screen. DO NOT  

  use eyebolts to mount screen. Using both mounting holes in the mounting  

  brackets makes for a much more stable installation. Never attempt to lift  

  screen along its length.

2

 The 

entire weight

 of the unit 

MUST BE

 supported by the end plates to provide  

  a secure installation. Anchoring of the intermediate case support brackets is  

  typically only needed to reduce any visible case deflection when the unit is  

  mounted into a ceiling pocket or ceiling tile opening. For installations that are  

  not recessed, the amount of case deflection is usually not noticeable.

3

  Screen should be positively and securely supported so that vibration or even  

  abusive pulling will not weaken installation.

4

  Installer must insure that fasteners used are of adequate strength and suitable  

  for the mounting surface chosen. 

Installer must also insure that wall or  

  ceiling structure are of adequate strength. 

Supporting hardware (chains,  

  cables, rods, etc.) must be essentially vertical.

5

  Entire bottom of case must be readily accessible after installation is complete.

6

  Front, back and top of case must be straight—not forced to warp or bow. Use  

  threaded rod and support brackets to keep large cases from warping. 

DO NOT  

  use support brackets to support the weight of the screen.

7

  Do not use case to support adjacent sections of ceiling.

8

  If optional ceiling flange trim kits are attached, use hardware provided.

9

  If case is painted, slots on bottom of case should be shielded to protect viewing  

  surface from paint splatters or overspray.

10

  Do not seal unit in ceiling until electrical connections have been made and  

  screen has been operated successfully.

Electrical Connections

Screen operates on 220V AC, 50 Hz., 1ph. current.

Junction box is located just above the closure panel, at the motor end of screen 

(left hand motor location only on Paragon). To properly remove closure panel, two 

people should follow the steps on page two of these instructions. The junction 

box access plate is held closed with pan head screws and may be opened with 

a Phillips screwdriver. Removal of access plate exposes brown, black and blue 

pigtail leads and green internal ground wire per attached wiring diagram.

Screen is shipped with internal wiring complete and control switch(es) fully boxed. 

Wire connecting screen to switch(es) and switch(es) to power supply should be 

furnished by installer. Connections should be made in accordance with attached 

wiring diagram, and wiring should comply with national and local electrical codes.

All operating switches should be “off” before power is connected.

Please Note: Do not wire motors in parallel.

Operation

When screen is first operated, 

be cautious! 

Cycle unit down and up several times 

to confirm satisfactory operation.

220V AC Single Station Control—

3-position up-off-down switch permits 

operation to be stopped at any point. Factory adjusted limit switches automatically 

stop screen when fully down or fully up.

220V AC Multiple Station Control 

(Not CE approved)

Switches are similar 

in appearance to 220 V AC Single Station Control. Screen stops when switch is 

released and may be restarted in either direction. Factory adjusted limit switches 

stop screen automatically when fully down or fully up.

24V Control

Three-button up-stop-down switch(es) stop at any point desired, 

operate in any sequence. Factory adjusted limit switches automatically stop screen 

when fully down or fully up. Installer should incorporate an all-pole disconnect in 

the fixed wiring.

Key Operated Switching 

(Not CE approved)

Two kinds of key-operated 

switches are optionally available with this unit. 

1

 The key-operated power supply 

switch controls power to the screen and switches. When it is “off”, the switches 

will not operate screen. Key may be removed from the switch in either “on” or “off” 

position. 

2

 A three-position key switch permits the screen to be operated directly 

by key. In this case, the screen’s operator must always have a key.

RS232/Ethernet—

Serial communication and network communication optionally 

available with wall switches, RF or IR remote.

Adjustments 

Please Note: Screen limits are factory set for optimum performance of the 

screen. A procedure is outlined below for minor tweaks, but any adjustment 

of these limits may negatively affect the flatness of the screen surface and 

could also void the warranty. Please check with Draper prior to resetting 

screen limits.

CAUTION: Always be prepared to shut screen off manually when new 

adjustment is being tested. Screen may be severely damaged if viewing 

surface is allowed to run too far up or too far down.

C

AUTION: Be sure all switches are in “off” position before adjusting limit 

switches.

Caution: Rough handling in transit may cancel/reset motor limit settings. 

To prevent viewing surface damage, be prepared to stop descending screen 

if surface begins to retract instead of stopping or if motor does not shut off 

when screen has fully retracted into case.

ADJUSTING “FULLY UP” POSITION

—Put a small screw driver in the groove of 

the yellow button on the motor and press vertically until hearing a "click". Raise 

the screen by pressing the "up" switch on unit. Press the "stop" switch when the 

screen is at the desired position. Then press the yellow button on motor until you 

hear a "click", then release.

ADJUSTING “FULLY DOWN” POSITION—

Put a small screw driver in the groove 

of the white button on the motor and press vertically until hearing a "click". Lower 

the screen by pressing the "down" switch on unit. Press the "stop" switch when the 

screen is at the desired position. Then press the white button on motor until you 

hear a "click", then release.

AT NO TIME SHOULD SCREEN BE UNROLLED ENOUGH TO EXPOSE ANY 

PART OF SCREEN ROLLER.

Installation/Operating Instructions

220V Paragon/Series E and V Electric Screen by Draper

Copyright © 2013 Draper Inc.  Form ParagonEV-220V_Inst13 

Printed in U.S.A.

 

 

 

®

203
mm

337
mm

305 mm

Eyebolts for hoisting screen

(not for use in mounting 

case) (do not lift screen by 

center of case. To insure a 

safe installation, the entire 

weight of the unit MUST BE 

supported by the end-plates).

Case support

brackets. NOT for 

use in supporting

weight of case.

Knockouts for electrical connections

(two per end) with plastic plugs*

*Left hand motor location only on Paragon

½" (12/7mm) threaded 

rod (for suspending

screen) by others.

3

/

8

" -16 (9.5mm) threaded rod

(use for adjusting 

deflection in extremely 

long units) by others.

Please see back page for dimensional diagrams of case and optional wall  

mounting bracket, wiring diagrams and instructions on removing and replac-

ing the bottom closure.

These Installation/Operating Instructions are available in the official language of 

the country where you purchase the product. Please contact your distributor to 

request a copy.

Vous pourriez demander les instructions d’installation et d’opération traduises 

dans la langue officielle du pays ou vous achetez le produit. Veuillez demander à 

votre distributeur.

Die Gebrauchsanweisung für Installation und Konstruktion sind in der offiziellen 

Sprache des Landes, indem Sie das Produkt gekauft haben, vorhanden. Fragen 

Sie die jeweilige Verkaufs-Abteilung.

If you encounter any difficulties installing or servicing your Paragon screen, call your dealer or 

Draper, Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-1689.

Suitable for use 

in environmen-

tal air space 

in accordance 

with Section 

300-22(c) of the 

National Electri-

cal Code, and 

Sections 2-128, 

12-010(3) and 

12-100 of the 

Canadian Elec-

trical Code, Part 

1, CSA C22.1.

Caution: Do not remove the roller assembly from the case unless neces-

sary for repairs. If the roller assembly is removed, be sure motor is fully 

re-seated in the bracket, and re-secure it carefully with the motor retaining 

spring and screw (see diagram below).

Please note: Maximum torque for 

tightening screw is 5 lb-inches.

Instructions 

continued 

on Page 2

US Patent No. 

6,873,461

These instructions are meant as a guide only. They do not imply any responsibility 

on the part of the manufacturer for improper installation or faulty workmanship at 

the jobsite.

Отзывы: