Installation/Operating Instructions

Baronet/HW 110V and 220V Electric Projection Screen by Draper 

Wall Installation:

Mount screen through holes in back of endcaps as shown. Installer should 
furnish appropriate hardware as re quired.

Recessed Installation:

Recess should permit access for removal of screen if necessary. Screen may 
be mounted as in sus pend ed or wall installation. Angles may be used (pro-
vided by others).

Electrical Connections

Screen operates on 110-120V AC, 60 Hz./220V AC, 50 Hz. current, depend-
ing on model ordered. Duty Cycle: On 26 seconds/off 3 minutes.
Junction box is located inside left endcap and cover plate is secured to 
endcap with two screws. Junction box contains pigtail leads and grounding 
screws, per wiring di a gram on reverse.
Screen is shipped with internal wiring complete and control switch(es) fully 
boxed. Wire connecting screen to switch(es) and switch(es) to power supply 
should be furnished by installer. Connections should be made in ac cor dance 
with attached wiring diagram, and wiring should comply with National and 
local electrical codes.
All operating switches should be “off” before power is con nect ed. Do NOT wire 
motors in parallel.

Hanging Screen 

General:

When locating view ing surface and checking clear ance for screen’s op er a-
 tion, remember surface is centered in case. Handle case care ful ly to protect 
its fi nish.
Regardless of mounting method, screen should be positively and securely 
sup port ed so that vibration or even abusive pulling on the viewing surface will 
not cause case to work loose or fall. Installer must insure that fas ten ers used 
are of adequate strength and suit able for mounting sur face cho sen.

Suspended Installation:

Suspend screens from holes in top of endcaps as shown. "S" hooks, chains 
(or cable) and turn buck les should be pro vid ed by installer. “S” hooks should 
go through the front holes on the endcaps (see drawing below), and both 
ends of the “S” hooks should be crimped for additional safety. Chains should 
be at tached to beams or other struc tur al mem bers. Turn buck les should be 
adjusted so screen hangs level.

If you encounter any diffi culties installing or ser vic ing your Bar on et/HW screen, call your 
dealer or contact Draper, Inc., Spiceland, In di ana, +1 765-987-7999 or fax +1 765-987-1689.

Copyright © 2011 Draper Inc. 

Form BaronetHW_Inst11 

Printed in U.S.A.

Caution

  Read instructions through completely before proceeding.

  Follow instructions carefully. Installation con trary to instructions in val i-

 dates warranty.

  Screen should be accessible for complete removal should fabric be-

 come damaged or should other ser vice be required.

  Screen should be installed level (using a carpenter’s level).

  Nothing should be fastened to screen dowel or viewing surface.

  Operating switch(es) packed separately in screen carton. Do not dis-

 card with packing material.

  Screen operates on 110-120V AC, 60 Hz. or 220V AC, 50 Hz. current, 

 

depending on model ordered.

NOTE

: Screen has been thoroughly inspected and tested at factory and 

found to be operating properly prior to shipment.

Operation

Before operating screen remove tape securing fabric and dowel to roller. If 
viewing surface hangs out of case 8" or 9" (20-23 cm), tape has prob a bly 
been bro ken by rough handling in ship ment, allowing surface to “un wrap” 
one turn about the roller. Manually wrap fabric back around the roller without 
turning the roller itself.

110-120V/220V Single Station Control —

 3-position up-off-down switch 

per mits operation to be stopped at any point. Factory adjusted limit 
switches au to mat i cal ly stop screen when fully down or fully up. 220V version 
is CE certifi ed.

110-120V/220V Multiple Station Control

—Switches are similar in ap-

 pear ance to 110V/220V Single Station Control. Screen stops when switch 
is re leased and may be re start ed in either direction. Factory adjusted limit 
switch es stop screen automatically when fully up or fully down.

24V Control —

 Three-button up-stop-down switch es stop at any point de-

sired, operate in any sequence. Factory adjusted limit switches au to mat i cal ly 
stop screen when fully up or fully down.

Key Operated Switching — 

Two kinds of key-operated switches are op tion-

 al ly available with this unit.

  The key-operated power sup ply switch controls power to the screen and 

switches. When it is “off ”, the switch es will not operate screen. Key may 
be re moved from the switch in either “on” or “off” position.

 A three-po 

si tion key switch per mits the screen to be operated directly by 

key. In this case, the screen’s operator must always have a key.

RS232/Ethernet—

Serial communication and network communication 

optionally available with wall switches, RF or IR remote.

Adjustments

Please Note: Screen limits are factory set for optimum performance of the 
screen. Any adjustment of these limits could void the warranty.  Please 
check with Draper prior to resetting screen limits.

CAUTION: Always be prepared to shut screen off manually when new 

adjustment is being tested. Screen may be severely damaged if viewing 
surface is allowed to run too far up or too far down.

C

AUTION: Be sure all switches are in “off” position before ad just ing limit 

switches.

“Down” limit switch: 

Down stopping position can be adjusted by turning 

white knob with a screw driver or hex wrench. Turning knob counterclockwise 
will  allow viewing surface to run farther down. Turning it clockwise will reduce 
the amount of exposed viewing surface. 

 “Up” limit switch:

 Up stopping position can be adjusted by turning red knob 

with a screw driver or hex wrench through the small grommet. Turning knob 
counterclockwise will allow surface to run farther into screen case. Turning it 
clockwise will allow viewing surface to stop farther out of screen case.

 

 

 

®

Minim

u

m 5 cm 

w

ide

slot for passage of

v

ie

w

ing s

u

rface if

s

u

spended a

b

o

v

e ceiling

Example of 
s

u

spension

a

b

o

v

e ceiling.

Ceiling tile
and grid
(

b

y others)

Back hole for 

w

all mo

u

nting.

Hard

w

are 

b

y others.

Top Hole for 

s

u

spended mo

u

nting. 

Hard

w

are 

b

y others.

Mo

u

nting angle

and hard

w

are

b

y others.

S

u

ggested for

recessed 
installations.

Crimp

Crimp

These Installation/Operating Instructions are available in the offi cial language 
of the country where you purchase the product. Please contact your 
distributor to request a copy.
Vous pourriez demander les instructions d’installation et d’opération traduises 
dans la langue offi cielle du pays ou vous achetez le produit. Veuillez 
demander à votre distributeur.
Die Gebrauchsanweisung für Installation und Konstruktion sind in der 
offi ziellen Sprache des Landes, indem Sie das Produkt gekauft haben, 
vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.

Baronet/HW 110-120V 
AC

 version is certifi ed by 

Underwriters’ Laboratories, Inc., 
for the U.S. and Canada.

Baronet/HW220V AC

 

version is CE certifi ed.

Отзывы: