Draper Access MultiView Series Скачать руководство пользователя страница 1

220 Volt Installation/Operating Instructions

Access/MultiView Electric Projection Screen & Masking System by Draper

Hanging Screen

When locating viewing surface and checking clearance for screen operation, 

remember surface is centered in the length of the case. Regardless of mount-

ing method used, the following points apply:

1

 Mounting brackets are packed separately in carton. Engage each  

  bracket with top of housing as shown below and tighten set screws. A  

  bracket should be within 46 cm of each end of screen case. Brackets  

  can be removed and case mounted with lag screws through top of case  

  (holes drilled on site).

Screen should be positively and securely supported so that vibration or 

  even abusive pulling on viewing surface or masking will not weaken 

 installation.

3

  Installer must insure that fasteners used are of adequate strength and 

  suitable for the mounting surface chosen. Supporting hardware (chains, 

  cables, rods, etc.) must be essentially vertical.

4

  Entire bottom of case must be readily accessible after installation is 

 complete.

Electrical Connections

Screen operates on 220V AC, 50 Hz., 1 ph current.
All connections are made in the junction box located just above the bottom
access panel at left end of screen. Remove the bottom access panel for ac-
cess to the junction box cover. (See Bottom Access Panel Removal instruc-
tions below).
Remove four (4) hex head screws that secure the cover to the junction box to 
expose two sets of brown, black, and blue pigtail leads and the green ground 
wire per wiring diagram on page 4.
If optional low voltage control or video interface control is specified and factory 
installed for either motor, please refer to wiring diagram on page 3.
Screen is shipped with internal wiring complete and control switch(es) fully 
boxed. Wire to connect screen to switch(es) and switch(es) to power supply 
should be furnished by installer. Connections should be made in accordance 
with attached wiring diagram, and wiring should comply with national and 
local electrical codes.

All operating switches should be “off” before power is connected.

Bottom Access Panel Installation/Removal

Bottom access panel hooks over the lower inside edge of the screen housing 
and then is pivoted downward until the engagement brackets on each end of 
the bottom panel click into place with the ball detents on each endcap. Make 
sure bottom access panel clicks in place at each end of its length.

With bottom access panel 
angled up approx. 20 degrees, 
engage hook on the panel 
with lip of the housing

Using the hook and lip as a pivot, 
pull the panel downward until the 
engagement brackets click into 
place with the ball detent 
on each endcap

Engagement bracket 
(one on each end of the 
bottom access panel)

Remove bottom access panel by pushing up at each corner of panel 
adjacent to slot in bottom of the housing. With bottom access panel angled 
up approximately at 20° it can be lifted off of the lip of the housing and then 
lowered out of the housing completely.

Access case as seen from below

These Installation/Operating Instructions are available in the official language 

of the country where you purchase the product. Please contact your distributor 

to request a copy.

Vous pourriez demander les instructions d’installation et d’opération traduises 

dans la langue officielle du pays ou vous achetez le produit. Veuillez 

demander à votre distributeur.

Die Gebrauchsanweisung für Installation und Konstruktion sind in der 

offiziellen Sprache des Landes, indem Sie das Produkt gekauft haben, 

vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.

Caution

Read instructions through completely before proceeding.

Follow instructions carefully. Installation contrary to instructions invali- 

  dates warranty.

Entire bottom of screen case should be unobstructed to permit access 

  to bottom panel for making electrical connections or servicing. 

Screen should be installed level (using a carpenter’s level).

Nothing should be fastened to screen dowel, viewing surface, or  

 masking.

Operating switches packed separately in screen carton. Do not discard 

  with packing material.

Screen operates on 220V AC, 50 Hz., 1 ph current.

NOTE

: Screen has been thoroughly inspected and tested at factory and 

found to be operating properly prior to shipment.

Copyright © 2014 Draper Inc.  Form AccessMultiView220v_Inst14  Printed in U.S.A.

5

  Front, back and top of case must be straight—not forced to warp or bow. 

6

  If case is painted on location, removal of roller/fabric assembly is recom- 

  mended prior to painting. If not removed, slot on bottom of case should be 
  shielded to protect viewing surface from paint splatters or overspray.

7

  Do not seal unit in ceiling until electrical connections have been made  

  and screen has been operated successfully.

 

 

 

 

Typical Installation

Alternate 

Installation

(additional 

set of 

brackets 

required but 

not included)

Slots along top of case permit 

brackets to be set at an angle

Case dimensions 

on page 4.

Dowel

Shipping

Bracket

Remove shipping brackets 

before operating screen.

Bottom flange of Access housing

Bottom access panel pushup 

points for panel removal

Caution: Beware of pinch

points at ends of closure

US Patent Nos. 6,137,629; 6,421,175; 6,532,109; 6,816,308; 7,559,707