Draper 400 Series Скачать руководство пользователя страница 1

IMPORTANT: Please read these instructions carefully to ensure the safe and effective use of this product and save 
these instructions for future reference. This manual has been compiled by Draper Tools and is an integrated part of the 
product with which it is enclosed and should be kept with it for future references.
This manual describes the purpose for which the product has been designed and contains all the necessary information 
to ensure its correct and safe use. We recommend that this manual is read before any operation or, before performing 
any kind of adjustment to the product and prior to any maintenance tasks. By following all the general safety 
instructions contained in this manual, it will ensure both product and operator safety, together with longer life of the 
product itself.
AlI photographs and drawings in this manual are supplied by Draper Tools to help illustrate the operation of the product.
Whilst every effort has been made to ensure accuracy of information contained in this manual, the Draper Tools policy 
of continuous improvement determines the right to make modifications without prior warning.

400 SERIES

CLAMP METER

41967

Содержание 400 Series

Страница 1: ...ommend that this manual is read before any operation or before performing any kind of adjustment to the product and prior to any maintenance tasks By following all the general safety instructions contained in this manual it will ensure both product and operator safety together with longer life of the product itself AlI photographs and drawings in this manual are supplied by Draper Tools to help il...

Страница 2: ... THIS MANUALS SAFETY CONTENT WARNING Information that draws attention to the risk of injury or death CAUTION Information that draws attention to the risk of damage to the product or surroundings 1 4 COPYRIGHT NOTICE Copyright Draper Tools Limited Permission is granted to reproduce this publication for personal educational use only Commercial copying redistribution hiring or lending is prohibited N...

Страница 3: ...LIGHT AND CLAMP HEAD LIGHTING 15 8 7 AUTOMATIC SHUTDOWN FUNCTION 15 8 8 BUZZER 15 8 9 PREPARATION FOR MEASUREMENT 15 8 10 AC AND DC CURRENT MEASUREMENT USING CURRENT CLAMP HEAD 15 8 11 AC VOLTAGE MEASUREMENT 16 8 12 DC VOLTAGE MEASUREMENT 16 8 13 FREQUENCY MEASUREMENT CLAMP FREQUENCY MEASUREMENT 16 8 14 VOLTAGE MEASUREMENT 17 8 15 FREQUENCY MEASUREMENT BY HZ DUTY 17 8 16 DUTY CYCLE MEASUREMENT 18 ...

Страница 4: ...where tools are hired out when the guarantee period is 90 days from the date of purchase This guarantee does not apply to normal wear and tear nor does it cover any damage caused by misuse careless or unsafe handling alterations accidents or repairs attempted or made by any personnel other than the authorised Draper warranty repair agent Note If the tool is found not to be within the terms of warr...

Страница 5: ...e measuring end and the earth 1000V DC or 750V AC Display LCD Maximum display value 5999 digits Polarity indication Automatic indication indicates negative polarity Over range display 0L or 0L Sampling time about 3 times sec Unit display with function power unit display Automatic shutdown time approx 15 minutes after no signal Power supply DC power supply 4 5V Battery type 1 5V AAA battery Battery...

Страница 6: ...ccuracy Resolution 60A 5 0 rdg 60 digits 0 01A 600A 1A Input impedance 10MΩ Max input voltage 600V AC RMS or 600V DC Frequency range 40 1000Hz Note In the low voltage range with the test leads is not connected to the circuit under test the Meter may have a fluctuating reading this is normal this it is caused by high sensitivity of the Meter it does not affect the actual measurement results DC Volt...

Страница 7: ...g this is normal this it is caused by high sensitivity of the Meter it does not affect the actual measurement results Input impedance 10MΩ Max input voltage 600V AC RMS or 600V DC Frequency range 40 1000Hz Range 10Hz 10kHz Input voltage range 2V AC RMS Higher frequencies require a larger input voltage Input impedance 10MΩ Maximum input voltage 600V AC RMS BY A range Clamp Jaws Frequency response 1...

Страница 8: ...imum input voltage 250V AC RMS Range Accuracy Resolution 600Ω 0 1Ω 6kΩ 0 8 rdg 3 digits 0 001kΩ 60kΩ 0 01kΩ 600kΩ 0 1kΩ 6MΩ 1 2 rdg 3 digits 0 001MΩ 60MΩ 2 0 rdg 5 digits 0 1MΩ Open circuit voltage about 0 4V Overload protection 250V DC or AC RMS Resistance Duty cycle Range Accuracy Resolution 0 1 99 9 3 0 rdg 3 digits 0 1 Overload protection 250V DC or AC RMS Continuity Test Range Resolution Func...

Страница 9: ...99 99mF Not calibrated 0 01mF Overload protection 250V DC or AC RMS Forward DC current 1mA Reversed DC voltage 3 0V Overload protection 250V DC or rms AC Range Accuracy Resolution 50 300 1 0 4d 1 301 1000 1 9 5d 1 58 600 1 2 6d 1 601 1832 1 9 6d 1 Temperature Measurement Diode Test Range Resolution Function 0 001V Displaying approximate forward voltage of diode 9 4 INTRODUCTION ...

Страница 10: ...es normally Do not use if the instrument is working abnormally Protection facilities may have been damaged If in doubt the instrument should be sent for maintenance Do not apply any voltage beyond the rated voltage indicated on the meter between any terminal and earth ground Warning When working above 30V use caution not to touch exposed contacts due to risk of electric shock Only use the approved...

Страница 11: ...on light Protection Guard Protects the user s hand from touching the danger zone Clamp trigger Measuring function selection dial SEL function Button Function buttons Display Probe sockets Current direction marking 6 IDENTIFICATION 11 ...

Страница 12: ...ng status Battery low indicator Diode measurement indicator Measure capacity indicator Degrees Celsius Degrees Fahrenheit Auto range indicator Relative mode Negative polarity indicator Data hold indicator Automatic shutdown indicator Linear Bar graph indicator FIG 1 6 1 LCD Liquid crystal display FIG 1 6 IDENTIFICATION 12 ...

Страница 13: ...nts out and check them If any part is damaged or missing do not attempt to use the tool and contact the Draper Helpline immediately see back page for details Retain the packaging material at least during the guarantee period in case the machine needs to be returned for repair Warning Some of the packaging materials used may be harmful to children keep them out of reach from children Disposed of an...

Страница 14: ...for more than 2 seconds to exit this mode 2 After entering the Peak Max mode the maximum value of the measurement is automatically saved 3 After entering the Peak Min mode the minimum value of the measurement is automatically saved 4 After entering the Peak Max Peak Min mode the measured difference is automatically saved 5 Press PEAK HOLD key for more than 2 seconds to exit this mode the Meter wil...

Страница 15: ...ower than 3 9V the symbol will appear and the batteries should be replaced 2 If the symbol shows that the input voltage or current should not exceed the specified value in order to protect the internal circuit from damage 3 Turn the measuring function selection dial to the required function and range to be measured 4 Connect the black lead to the com probe socket and the red lead to the VΩ probe s...

Страница 16: ...p is fully closed 3 Press the Hz button to select the frequency measurement function 4 The measurement result is read from the LCD Note The instrument can measure only one current conductor at a time If two or more current conductors are clamped at the same time the measurement result may be wrong The frequency measurement range is 10Hz 1kHz If the measurement frequency is less than 10Hz the LCD w...

Страница 17: ...MHz but it cannot guarantee the accuracy of the measurement The maximum input voltage is 250V AC rms 8 14 VOLTAGE MEASUREMENT THROUGH THE AC VOLTAGE RANGE Warning Risk of electric shock When measuring high voltage extra care should be taken to avoid electrical shock Do not attempt to use this meter on a voltage higher than the AC600V rms value 1 Rotate the measurement function selection dial to th...

Страница 18: ...ty ratio is higher than 94 9 OL will be displayed The input signal frequency measurement range is 10 1kHz if the measurement is higher than 1kHz frequency the measurement accuracy cannot be guaranteed The maximum input current is 600A AC rms 8 17 VOLTAGE MEASURED DUTY CYCLE THROUGH THE AC VOLTAGE RANGE Warning Risk of electric shock When measuring high voltage extra care should be taken to avoid e...

Страница 19: ...ent range is 10 10MHz if the measurement frequency is higher than 10MHz the measurement accuracy is not guaranteed The maximum input voltage is 250V AC rms 8 19 RESISTANCE MEASUREMENT Warning Risk of electric shock When measuring the impedance on the line make sure that the circuit power is off and the capacitors on the circuit are fully discharged 1 Rotate the measurement function selection dial ...

Страница 20: ... display OL this can be used to distinguish between the anode and cathode diodes Note The instrument shows the forward voltage drop of the measured diode 8 21 CONTINUITY TEST Warning Risk of electric shock Make sure the circuit power is off and the circuit capacitors completely discharged 1 Rotate the measuring function selector dial to the continuity position and ensure that the power to the circ...

Страница 21: ...pening the battery cover and replacing it with a new one Follow these steps to replace the battery 1 Turn off the instrument 2 Remove all test leads from the input jacks 3 Loosen the screws that secure the battery cover with a screwdriver 4 Remove the battery cover 5 Disconnect and remove the old battery 6 Replace with three new AAA batteries pay attention to the battery positive and negative Do n...

Страница 22: ...ipment in with domestic rubbish Resistance in Ohms Voltage AC Warning Read instruction manuals before operating and servicing this equipment Voltage DC Continuity test buzzer Auto power off Diode test Low battery display A Current AC Inspection light Work light Clamp size 36mm C F Temperature Hz Frequency Capacitance Bar graph 0 10 20 30 40 A Current DC Back light Data hold Screen lock 10 EXPLANAT...

Страница 23: ... to national regulations Contact your local authority for details of collection schemes in your area In all circumstances Do not dispose of power tools with domestic waste Do not incinerate Do not abandon in the environment Do not dispose of WEEE as unsorted municipal waste Waste Electrical Electronic Equipment NOTES 11 DISPOSAL 23 ...

Страница 24: ...vice Warranty Repair Agent For aftersales servicing or warranty repairs please contact the Draper Tools Helpline for details of an agent in your local area YOUR DRAPER STOCKIST Published by Draper Tools Limited No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior...

Отзывы: