DRAKE 1002613B Скачать руководство пользователя страница 1

Rev: 

072920

  /  651243000C-1

© 2018 R.L. Drake Holdings, LLC.

800-523-6049

www.rldrake.com

PEG PLUS Model

Public Educational & Governmental Access Encoder

INSTRUCTION MANUAL

Model 

Item # 

  Description

PEG PLUS 

1002613B    HD PEG Channel Encoder with HD-SDI Input or Composite 

  Video with Left + Right Audio and IP Output

Содержание 1002613B

Страница 1: ...LLC 800 523 6049 www rldrake com PEG PLUS Model Public Educational Governmental Access Encoder INSTRUCTION MANUAL Model Item Description PEG PLUS 1002613B HD PEG Channel Encoder with HD SDI Input or Composite Video with Left Right Audio and IP Output ...

Страница 2: ...age Cross Reference Hyperlinking Usage This guide makes use of hyperlinks for the Table of Contents some cross reference linking between sections and external hyperlinking to web addresses This has been done to assist the reader in finding the information they are seeking in a much quicker way In addition to hyperlinking the Table of Contents also makes use of the bookmarking feature present in th...

Страница 3: ...ATION SETUP INSTALLATION POWER UP 9 LOGIN SCREEN 10 UNIT CONFIGURATION STATUS TAB 11 STATUS TAB WITH ZIXI 12 ENCODER TAB 12 AV INPUT 12 ENCODING 13 ENCODING ZIXI 19 COMPOSITING 21 SYSTEM TAB 22 NETWORKING 22 REMOTE MANAGEMENT 24 SAVE RESTORE 24 SET SYSTEM TIME 25 LOG TAB 26 ADMINISTRATION PANEL ADMIN PANEL 26 FIRMWARE UPDATES FIRMWARE UPDATE TAB 28 SERVICE WARRANTY SERVICE 30 LIMITED WARRANTY 31 ...

Страница 4: ...he antenna or cable system This will prevent damage to the product due to lightning and power line surges 16 Power Lines An outside antenna system should not be located in the vicinity of over head power lines other electric light or power circuits where it can fall into such power lines or circuits 17 Overloading Do not overload wall outlets extension cords or integral convenience receptacles as ...

Страница 5: ... lignes ou circuits électriques Entrer en contact avec de tels circuits ou lignes électriques pourrait être fatal 17 Surcharge Ne pas surcharger les prises de courant murales les rallonges électriques ou les prises de courant intégrées Un risque d incendie ou de choc électrique pourrait résulter d une telle surcharge 18 Insertion d objet ou de liquide Ne jamais insérer d objet par les ouvertures d...

Страница 6: ... 100 1000 Transceiver 10 100 1000BASE T SFP RJ 45 100M COPPER 1002621 SFP MM 850 550M 1000BASE SX SFP 850NM 550M MMF DDM 1002622 SFP SMF 1310 10KM 1000BASE LX SFP 1310NM 10KM SMF DDM 1002670 SFP SMF 1310 40KM 1000BASE LX SFP 1310NM 40KM SMF DDM 1002623 SFP SMF 1550 80KM 1000BASE ZX SFP 1550NM 80KM SMF DDM 1002624 SFP SMF CWDM 1470nm 80KM 1 25GBASE CWDM SFP 1470NM 80KM SMF DDM 1002625 SFP SMF CWDM ...

Страница 7: ...Description Features Model Item Description PEG PLUS PEG RP 2 1002613B 1002613B Z 1002644B MPEG 2 or H 264 HD PEG Encoder with HD SDI or Composite Input and IP Output MPEG 2 or H 264 HD PEG Encoder with Zixi Option Rack Mount Panel for 2 PEG PLUS units PEG RP 2 with 2 PEG PLUS units FEATURES MPEG 2 or H 264 video encoding Selectable SD HD SDI or Composite video input Encodes two HD or SD streams o...

Страница 8: ... factory IP address 172 16 70 1 Subnet Mask 255 255 255 0 The login credentials will also be enabled to the default username admin and password pass NOTE The old IP address login and password will still be present in the encoder settings Status LEDs provide a status of tasks performed by the PEG PLUS encoder in real time Power LED is illuminated when the power is ON Input LED is illuminated when i...

Страница 9: ...ower adapter supplied with the PEG PLUS Encoder For safe and reliable operation do not place objects within 1 inch of the unit that blocks the airflow A 1RU 1 75 open space must be provided above the PEG PLUS encoders when mounted in a 19 inch rack or cabinet to allow air flow for encoder heat dissipation Drake s PEG RP 2 accessories or a standard 19 rack shelf can be used for mounting 2 PEG PLUS ...

Страница 10: ...in how to do this for a PC with Windows 7 Windows 8 x or Windows 10 operating software a On your computer navigate to the Network and Sharing Center Note This can be found using the search box in the Start Menu or for Windows 8 x the Start Screen b Once open click on Change Adapter Settings on left hand side of the window c Right click on the Local Area Connection and then click on the Properties ...

Страница 11: ...he controls under the System menu and will be displayed in UTC time format 1 2 5 6 3 7 4 Figure 2a Status Tab Read Only 2 1 3 4 6 7 8 9 11 12 13 5 10 Input Status Box Status Indicates the status of the input Firmware Version Indicates the current firmware version SDI Input and Format Input indicates if the video is present and locked Format indicates resolution see Figure 2b Composite Input and Fo...

Страница 12: ...oder Tab AV Input Status Tab with Zixi AV Input Source Settings 1 2 Figure 3 Encoder Tab AV Input 2 1 3 5 4 6 ZIXI Stream Status Box Status Indicates the status of the input Host IP User defined IP address or host name The public IP address of the device Decoder or Broadcaster you are streaming to Conn Up Time Indicates the uptime of connection Reconnects Indicates the number of reconnections Bitr...

Страница 13: ...dB This is based on the standard film audio formats which normally are between 25 and 31 dB 5 6 3 4 Figure 4a Encoder Tab Encoding Audio Encoder Settings 1 3 2 1 2 3 Audio Encoder Settings Figure 4a AV Input Source Settings continued see Figure 3 Stream 1 MPEG 4 AVC HD See Figure 4b next page Video Encode Video Bitrate HD Input Range is 3 5 to 13 incremented by 0 1 NOTE Once an input is applied on...

Страница 14: ...ata NOTE All PIDs are displayed in Hex format If you type a decimal format into the field the GUI will automatically convert your decimal format to a Hex value PIDs are expressed in both decimal hex formats to the right of the entry field Service Info Type Default value is None If set to DVB SI the following fields are enabled DVB Network Name user specified field for the Network Name in the DVB N...

Страница 15: ... Identifier PID used to transmit all Program Map Tables in the stream Video PID Configures the PID used to transmit Video and associated data Audio PID Configures the PID used to transmit audio and associated data NOTE All PIDs are displayed in Hex format If you type a decimal format into the field the GUI will automatically convert your decimal format to a Hex value PIDs are expressed in both dec...

Страница 16: ...D used to transmit all Program Map Tables in the stream Video PID Configures the PID used to transmit Video and associated data Audio PID Configures the PID used to transmit audio and associated data NOTE All PIDs are displayed in Hex format If you type a decimal format into the field the GUI will automatically convert your decimal format to a Hex value PIDs are expressed in both decimal hex forma...

Страница 17: ... PIDs are displayed in Hex format If you type a decimal format into the field the GUI will automatically convert your decimal format to a Hex value PIDs are expressed in both decimal hex formats to the right of the entry field Service Info Type Default value is None If set to DVB SI the following fields are enabled DVB Network Name user specified field for the Network Name in the DVB NIT table DVB...

Страница 18: ...determined by the downstream network device Destination Port Destination port assigned to the IP or Hostname of the IP Output TTL Time to Live TTL is an upper bound on the time that an IP packet can exist in an IP network The value is set by the sender of the packet and reduced by every host on the route to packet s final destination If the Time to Live reaches zero before the packet arrives at it...

Страница 19: ...ort Password Used to prevent unauthorized connections but does not encrypt the stream The encoder s password MUST match the decoder s password Note An empty field is equivalent to no password Max Latency Used to set maximum allowed latency of the stream over the Zixi protocol Units are in milliseconds and are numeric values ranging from 100 to 5000 in increments of 100 Default option is Auto a Set...

Страница 20: ...Auto a Setting Max Latency to a low value means more forward error correction FEC is needed to guarantee stream delivery b Setting Max Latency to a higher value allows the Zixi layer to use re transmission instead of in addition to FEC NOTE In general higher latency yields lower CPU load on the encoder and less overhead on the data rate Hostname IP Address User defined IP address or host name Port...

Страница 21: ...ports PNG file format and displays only when an image file has been uploaded PLEASE NOTE Overlay for No Input 480i image resolution must be 720x480 Overlay for 720p image resolution must be 280x720 Overlay for 1080i image resolution must be 1920x1080 Figure 5 Encoder Configuration Compositing Encoder Tab Compositing ...

Страница 22: ...22 800 523 6049 www rldrake com Figure 6 System Tab Networking System Configuration 1 3 2 4 5 6 7 System Tab Networking The system configuration tab allows the user to set Ethernet and SNMP settings ...

Страница 23: ... internet System Tab Networking SFP Video Network Settings Mac Address read only field that indicates the MAC Address of the SFP Output Port DHCP Enable Enables or Disables DHCP on the SFP Output IP address the static IP address that is assigned to the SFP Network Output Default 172 16 80 1 Subnet Mask the subnet mask address of the SFP Network Output Default Gateway The Gateway Address of the SFP...

Страница 24: ... remote managed by using SSH tunneling Secure Socket Shell SSH is a network protocol that provides administrators with a secure way to access a remote computer over an unsecured network such as the Internet System Tab Networking 1 2 Figure 7 System Tab Save and Restore Settings 1 2 Unit Description Unit Name and User Location are user defined fields to make identification easier SNMP Settings Simp...

Страница 25: ...r s ssh TCP port in the PEG s SSH Port field standard is 22 4 Enter the username and password for the ssh server account in the PEG s SSH User and SSH Password fields 5 Enter the port number of the remote ssh server side tunnel termination 6 Point a web browser at the ssh server s Remote Port configured in step 5 for instance http SSH_SERVER_ NAME REMOTE_PORT The System Time can be synced up to th...

Страница 26: ...ssword is the Administrator s Current Password 10 characters maximum Password is case sensitive and will not be displayed Factory Default pass Additional Info Download SNMP MiB Click on the link to save the encoder s mib file Debug Info Link to a text only view of Debug Info Debug Log Archive Downloadable tar gz archive file of the Debug Log Log Messages Max Lines to Display Sets the maximum numbe...

Страница 27: ...e user to view the unit settings but does not allow any changes Login is case sensitive Factory Default guest Current Password is the Current Guest Password 10 characters maximum Password is case sensitive and will not be displayed Factory Default pass New Password used only if the user wants to change the current Guest password Must enter a new password 10 characters maximum Password is case sens...

Страница 28: ...Defaults or to Reboot the unit if applying settings through an import of a configuration file See System Tab Save Restore section Licensed Features To enable optionally purchased add on features such as Zixi type in the License Key number provided by Drake and then press the Update Key button 9 10 Firmware Updates For more information regarding the latest product firmware releases please visit our...

Страница 29: ...29 800 523 6049 www rldrake com ...

Страница 30: ...ed to you 6 Securely pack the product in its original undamaged box returning the product without its original packaging in good new condition may cause the incursion of additional fees Pack this box within another shipping container or box Mark the shipping box or container with your RMA Number Place the RMA Number near the return address in large bold print approx 2 in height Ship your CREDIT RE...

Страница 31: ...NSIBLE FOR ANY CONSEQUENTIAL INDIRECT INCIDENTAL PUNITIVE DIRECT OR SPECIAL DAMAGES BASED UPON BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT TORT LIABILITY OR OTHERWISE OR ANY OTHER LEGAL THEORY ARISING DIRECTLY OR INDIRECTLY FROM THE SALE USE INSTALLATION OR FAILURE OF ANY PRODUCT ACQUIRED BY BUYER FROM BT All claims for shortages defects and non conforming goods must be made by the cus...

Страница 32: ...R L DRAKE HOLDINGS LLC Sales and Service 800 523 6049 Fax 732 679 4353 www rldrake com ...

Отзывы: