Connecting the Batteries in Series 

 

Why Connect in Series?  

When batteries are connected in series, current capacities remain the same, but the system voltage is additive. For 
example, two BBGC3 batteries connected in series form a nominally 24V system (shown in Fig. 4) and should be charged 
using a bulk and absorption voltage of 28.8V, and a float voltage of 27.2V.  

 

How to Make a Series Connection  

Note:  Battle Born GC3 Batteries are capable of being connected in series up to 48V. 

DO NOT

 exceed a 48V setup or you will void the battery’s 

warranty

.  

 

1.

 

Before making any connections, make sure to charge each battery up to 14.6V with a proper lithium charger. ALL 
BATTERIES SHOULD BE AT THE SAME STATE OF CHARGE PRIOR TO CONNECTING, otherwise you will encounter 
balance issues within your system. You can check your battery’s state of charge with a multimeter. 

2.

 

Identify the positive and negative terminals. These are labeled and color-coded

 red for positive (+)

black for 

negative (–).

  

3.

 

Determine the appropriate finishing hardware set you will use. Verify that your bolt can fully seat into 
the nylok insert of the nut. If multiple lugs are used, longer bolts may be required for the bolt to fully seat into 
the nylok insert of the nut.  

4.

 

Make the proper cable connections to the negative terminal of the first battery. Please reference Fig. 1 for the 
proper order of hardware.  

5.

 

When connecting to your battery terminals, 

DO NOT

 

finger tighten. Use a torque wrench to torque your hardware 

to the specification of 9 to 11 ft-lbs. Failure to adequately secure connections can result in severe damage and will 
void your warranty.  

6.

 

Connect the other end of your cable to the positive terminal of the other battery you are connecting to. Repeat step 
4.  

7.

 

Repeat steps 3-6 for additional batteries, but 

DO NOT

 exceed 48V. An example of a correct series connection can be 

found below in Fig. 4.  

 

 
 

 

 

 

 

Figure 4:

 Two GC3 Batteries Connected in Series to create a 24V 270Ah Battery Bank

 

How to Properly Charge the Batteries 

 

To properly charge your Battle Born Batteries, you will want to verify that any charging component in your system is 
capable of being programmed for the following specifications. Charging components can include, but are not 
limited to converters, inverter chargers, solar charge controllers, DC to DC chargers, etc.   

 

Bulk/Absorption: 14.2V – 14.6V 

 

Absorption Time: 60-90 minutes per battery (for parallel string)   

 

Float: 13.4V – 13.8V 

 

Equalization: 14.4V/ Disabled   

 

Temperature Compensation: 0/Disabled 

NOTE: Not all chargers are capable of multistage charging. If yours is not, you will want to verify it can be programmed for the Bulk/Absorption voltage and have the 
other items mentioned disabled if applicable. Consult your charger’s manual or the manufacturer

Содержание Battle Born Batteries GC3

Страница 1: ...Model GC3 270Ah 12V Deep Cycle LiFePO4 Battery Manual and Installation Guide Dragonfly Energy Corp Phone 855 292 2831 Email info battlebornbatteries com Dragonfly Energy Battle Born Batteries...

Страница 2: ...Heat Enable Instruction manual prior to use and installation Table of Contents What is in the Box 3 What Do I Need for Installation 3 Connecting Load Specified Cables to the Batteries 3 Connecting the...

Страница 3: ...dentify the positive and negative terminals These are labeled and color coded red for positive black for negative 2 Determine which finishing hardware set you will use Verify that your bolt can fully...

Страница 4: ...r negative 2 Determine the appropriate finishing hardware set you will use Verify that your bolt can fully seat into the nylok insert of the nut If multiple lugs are used longer bolts may be required...

Страница 5: ...nections to the negative terminal of the first battery Please reference Fig 1 for the proper order of hardware 5 When connecting to your battery terminals DO NOT finger tighten Use a torque wrench to...

Страница 6: ...voiding the warranty High Temperature Charging and Discharging 135 F 57 2 C The BMS will not allow a charging or discharging current if the internal temperature of the battery has reached 135 F 57 2 C...