User Manual for LoRaWAN End Nodes - CPL01 LoRaWAN Outdoor Pulse/Contact Sensor
• LoRaWAN Downlink instruction for different platforms:
There are two kinds of commands to configure CPL01, they are:
•
General Commands
.
These commands are to configure:
• General system settings like uplink interval.
• LoRaWAN protocol & radio related command.
They are the same for all Dragino Devices which support DLWS-005 LoRaWAN Stack(Note**). These commands
End Device AT Commands and Downlink Command
•
Commands special design for CPL01
These commands are only valid for CPL01, as below:
3.1 Set Transmit Interval Time
Feature: Change LoRaWAN End Node Transmit Interval.
AT Command: AT+TDC
Downlink Command: 0x01
Format: Command Code (0x01) followed by 3 bytes time value.
If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type
code is 01.
• Example 1: Downlink Payload: 0100001E // Set Transmit Interval (TDC) = 30 seconds
• Example 2: Downlink Payload: 0100003C // Set Transmit Interval (TDC) = 60 seconds
3.2 Set Password
Feature: Set device password, max 9 digits
AT Command: AT+PWORD
Command Example
Function
Response
AT+PWORD=?
Show password
123456