9023744 - 3rd edition - October 2005
Page 13 of 40
Installing Electrical Connections
Connection between Transmitter Polytron Ex R and Sensing Head SE Ex
●
Make sure to use such Ex-sensors only which are listed in the Order List, page 31.
●
Shorten the cable if required, and attach it in line with the illustration:
For reasons of ex-protection, the pre-mounted cable must neither be extended
nor replaced by another cable.
Non-observance will affect the ex-approval!
Installing Ex-sensor in the Transmitter
1
Loosen hexagon socket-head bolts on upper side and remove upper section.
2
Unscrew bayonet ring, remove cover plate.
3
Remove Ex-sensor from packaging, screw it into the adapter plate delivered with
the transmitter, observe gasket and lock with bayonet ring.
●
Make sure to use such Ex-sensors only that are specified in the Order List,
page 31.
●
Adjust constant current or constant voltage of transmitter according to the speci-
fications in the technical data of the Ex-sensor used:
brown
–
terminal 1
white
–
terminal 2
green
–
terminal 3
0
1
1
2
3
7
44_1
.eps
1 2 3
0
1
223
7
44_1
.eps
1
2
0
1
323
7
44_1
.eps
3
3
Содержание Polytron Ex
Страница 29: ...9023744 3rd edition October 2005 Page 29 of 40 Technical Data Sensing Head SE Ex 45 mm 68 mm 03923744_1 eps...
Страница 33: ...9023744 3rd edition October 2005 Page 33 of 40 EC Type Examination Certi cate BVS 03 ATEX E 160 X...
Страница 34: ...Page 34 of 40 9023744 3rd edition October 2005...
Страница 35: ...9023744 3rd edition October 2005 Page 35 of 40 EC Type Examination Certi cate BVS 03 ATEX E 160 X...
Страница 36: ...Declaration of Conformity Page 36 of 40 9023744 3rd edition October 2005 Declaration of Conformity...