Dräger Oxyboks K 35 A
i
en
Instructions for Use
3
Страница 1: ...Dräger Oxyboks K 35 A i en Instructions for Use 3 ...
Страница 2: ......
Страница 3: ...räger spare parts and accessories or the pro per functioning of the product may be impaired Do not use a faulty or incomplete product and do not modify the product Notify Dräger in the event of any component fault or failure 1 2 Definitions of alert icons The following alert icons are used in this document to provide and highlight areas of the associated text that require a greater awareness by th...
Страница 4: ...of 25 minutes The usage period can be significantly extended depending on the users breathing rate The Dräger Oxyboks K 35 A is carried on a belt on the right or left hand side of the body 2 3 Intended use The Dräger Oxyboks K 35 A is an emergency device intended for escape from areas with smoke toxic gases or oxygen deficiency 2 4 Limitations on use Do not use the Dräger Oxyboks K 35 A in air whi...
Страница 5: ... in the atmosphere may penetrate the open oxygen self rescuer and impair its function Inspect the oxygen self rescuer daily Use the oxygen self rescuer only once To avoid risk of fire make sure that no flammable materials petrol grease solvents etc can get into the oxygen self rescuer before or during operation There is also danger of ignition if the oxygen releasing chemicals come into contact wi...
Страница 6: ...n one go doing so will automatically activate the starter cartridge and the yellow breathing bag will fill with oxygen after about 6 seconds The loose packaging will fall off or may be removed NOTICE Donning the device incorrectly may cause delay when using the oxygen self rescuer in emergencies Be sure to perform the following steps in the described sequence i i 00421371 eps CAUTION The activated...
Страница 7: ...he mouthpiece with your lips 3 3 4 Fitting the nose clip 1 Pull the nose clip apart and fit over your nostrils so that your no se is completely sealed 2 Breathe steadily 3 3 5 Fitting and tightening the head harness 1 Take off your helmet 2 Untangle head harness and pull over head 3 Pull the red ends of the band evenly towards the head harness until tight 4 Put your helmet on again 00621371 eps 00...
Страница 8: ...dry This shows that the oxygen self rescuer is functioning correctly A possible strange taste is normal and harmless Do not damage or compress the breathing bag otherwise vital oxygen is lost If you need to vomit take the mouthpiece out of your mouth and close it with your thumb Do not vomit in the oxygen self rescuer In order to ensure that no harmful air is inhaled from the environ ment do not i...
Страница 9: ... 1 3 Replacing the bump protector 63 04 633 1 Open the velcro latches and remove the old bump protector 2 Mount the new bump protector Pay attention to the correct fitting of the bump protector 4 1 4 Attaching the belt Push the belt through the two loops of the housing 5 Transport Oxygen self rescuers are subject to international transport regulations during transport Unused oxygen self rescuers a...
Страница 10: ... returned Please contact the national marketing organisations and Dräger for further information Prepare damaged opened used up or expired oxygen self rescuers as follows For opened or damaged oxygen self rescuers trigger the starter before the transport For unopened devices the starter does not need to be triggered Put the oxygen self rescuer into a hermetically sealed foil pouch then place the p...
Страница 11: ...riod 5 5 mbar max 10 mbar CO2 content in inhaled air in inhaled air towards the end of the usage period less than 1 Vol max 2 5 Vol Temperature of inhaled air at the end of the usage period max 75 C dry air Weight unopened during use approx 2 3 kg approx 1 4 kg Dimensions W x H x D 240 x 198 x 110 mm Life time carried daily1 stored in depot 1 Single shift operation max 8 h a day 5 working days a w...
Страница 12: ...ber 2021 Edition 01 August 2014 Subject to alteration Dräger Safety AG Co KGaA Revalstraße 1 23560 Lübeck Germany Tel 49 451 882 0 Fax 49 451 882 20 80 www draeger com Notified Body South African Bureau of Standards SABS Private Bag X191 Pretoria 0001 South Africa ...