![DR. SAFE CCV018 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/dr-safe/ccv018/ccv018_assembly-instructions_2526082001.webp)
CYLINDER STORAGE CABINET
MODEL: CCV018
Assembly Instruction
s
DR. SAFE
“For A safe Environment!”
A
B
C
D
E
F
.
.
.
Back panel
Base
Chain
Door
Side panel
Mid-panel
2 PCS
1 PC
4 PCS
2 PCS
2 PCS
1 PC
G
H
I
1/4"× 3/4"
Top panel
Bolt and nut
Washer
1 PC
41 Pairs
41 PCS
*Caution: Two person assembly is recommended.
1. In an open assembly area free of obstructions, place the base (B) upright as
shown. Assemble each side panel (E) and mid-panel (F) by hand-tightening the
bolts, washers and nuts provided (H & I). Panels should be mounted such that
the flat part of chain support rail will face upward.
B
Flat edge of rail facing upward
F
E
G
2. Assemble the top panel (G) to the side panels (E) and mid-panel (F). Hand-tighten the
bolts, washers, and nuts provided (H & I). Ensure the unit is square and firmly tighten
the bolts connecting the side and mid panels to the base. Tighten the bolts connecting
the side and mid panels to the top panel. Set unit upright.
A
Flat edge of rail facing upward
3. Connect the back panels (A) to side panels (E) and mid-panel (F) using bolts,
washers, and nuts provided (H & I). Ensure the unit remains square and firmly
tighten the nuts. Note: out of square assembly will prevent the door from closing properly.