Purification Plate

PCO Cell

Cleaning

WARNING! Do not operate the unit unless the 

following are properly installed: PCO CELL, 

PURIFICATION PLATE, REAR FILTER ASSEMBLY 

(with all three pieces in place), and the REAR COVER.

CAUTION! The unit should be powered off and the 

POWER CORD should be disconnected whenever 

cleaning/disassembling/reassembling/servicing.

Unit Exterior

Wipe down the exterior with a damp cloth or use 

compressed air or a vacuum cleaner to remove dust. A 

non-abrasive cleaner may be used on the surfaces of the 

exterior, but do not let non-alcohol based cleaners come 

in contact with the IONIZATION NEEDLE at the top 

center of the FRONT GRILLE.

Filter Assembly

Clean water or compressed air may be passed through 

the filter assembly or through the individual parts of 

the filter when it is disassembled. To disassemble the 

FILTER ASSEMBLY grasp the assembly by the sides 

of the rim around the filter and separate the rim from 

the FILTER ASSEMBLY. The three filters (mesh, foam, 

and honeycomb) can then be removed and cleaned 

separately. If using water you must allow the filters to 

dry separately before reassembly. When reassembling, the 

HONEYCOMB FILTER goes in first, then the FOAM 

FILTER, and finally the thin MESH FILTER. Then 

simply reattach the rim to the FILTER ASSEMBLY. 

Ionization Needle

Using a cotton applicator (Q-Tip), apply a small amount 

of clear alcohol based cleaner (or rubbing alcohol) to the 

IONIZATION NEEDLE. You may also use compressed 

air to blow off any dust that may accumulate near the 

IONIZATION NEEDLE.

Unit Interior

Using a damp cloth, a clear alcohol based cleaner, or 

compressed air/vacuum cleaner carefully clean the walls 

and components inside of the unit, after completing the 

DISASSEMBLY procedures.

PCO Cell

Using compressed air or a vacuum blow/suck the dust 

out of the PCO Cell. Do not use any liquid to clean the 

PCO CELL.

Purification Plate

Using a 50/50 mix of warm water and clear ammonia, 

soak the PURIFICATION PLATE from 1-8 hours. 

Using a soft-bristle brush, scrub the wire mesh to remove 

debris lodged inside the mesh. Rinse thoroughly and 

allow to dry completely before reinstalling. Using a soft 

cloth and rubbing alcohol, clean the contacts on the 

interior of the unit that touch the PURIFICATION 

PLATE when installed. 

Troubleshooting

WARNING! Do not operate the unit unless the 

following are properly installed: PCO CELL, 

PURIFICATION PLATE, REAR FILTER ASSEMBLY 

(with all three pieces in place), and the REAR COVER.

CAUTION! The unit should be powered off and the 

POWER CORD should be disconnected whenever 

cleaning/disassembling/reassembling/servicing.

Unit Fails to Turn On

1. Verify that the POWER PLUG is plugged into an 

operational wall outlet.

2. Ensure that the POWER CORD is properly 

connected to the POWER ADAPTER.

3. Ensure that the POWER ADAPTER PLUG is fully 

seated in the receptacle on the back of the unit.

4. Verify the POWER BUTTON has been activated on 

the CONTROL PANEL.

5. If POWER BUTTON on the CONTROL PANEL 

fails, use the POWER BUTTON on the REMOTE 

CONTROL. If the unit activates when using the 

POWER BUTTON on the REMOTE CONTROL 

but not the CONTROL PANEL, the CONTROL 

PANEL is inoperational. Contact Mercola.com  

customer service.

Unit is Operating in High Mode or Away Mode, but 

no Noticeable Purification is Being Produced

1. Ensure that the PURIFICATION PLATE is clean. 

(See “CLEANING: PURIFICATION PLATE”)

2. Try installing a new PURIFICATION PLATE to 

find whether the PURIFICATION PLATE needs 

replacing.

3. Check the electrical contact arms which touch the 

plate to ensure that they are making proper contact 

with the metal weave on the PURIFICATION 

PLATE.

4. Ensure the electrical contact arms which touch the 

plate are clean. To be sure, clean them with a soft 

cloth and rubbing alcohol.

5. Operating the purifier in a darkened room, 

look through the FRONT GRILLE at the 

PURIFICATION PLATE. If the PURIFICATION 

PLATE is operating properly, it will produce a dim 

purple glow.

The Purification Plate Generates an Electrical Arc, 

Arcing Noise, or Burning Odor

The PURIFICATION PLATE is damaged and must 

be replaced. The unit may or may not display the 

REPLACE PLATE LCD Reminder.

The PCO Cell is not Lighting Up

1. Ensure the PCO CELL POWER CONNECTOR 

is properly seated in the PCO CELL POWER 

CONNECTOR OUTLET. (See “DISASSEMBLY/

ASSEMBLY”)

2. If the PCO CELL still fails to properly operate, 

you will need to replace it. Contact Mercola.com 

customer service.

Ionization Needle Creates an Electrical Arc

The IONIZATION NEEDLE needs to be cleaned. (See 

“CLEANING: IONIZATION NEEDLE”) 
Be sure to complete all of the cleaning procedures 

described in “CLEANING” every 30 days of operation.

Fan Does Not Operate Properly

1. Try adjusting the fan speed using the CONTROL 

PANEL or REMOTE CONTROL

2. Remove the FRONT GRILLE (See 

“DISASSEMBLY/ASSEMBLY”) and ensure there 

are no obstructions to the movement of the FAN. 

Clean the FAN by grasping it gently by the center 

(hub) and sliding it straight out of the front of the 

unit. Clean it thoroughly and also clean the mount 

that it sits on.

3. If FAN continues to operate improperly or not at all, 

contact your distributor or Mercola.com customer 

service

Содержание Pure & Clear PC-AP2000

Страница 1: ...s 5 Initial Setup Placement Settings 8 Operations 9 Maintenance 9 LCD Reminders 9 Disassembly Assembly 10 Cleaning 12 Troubleshooting 13 Consumer Information 14 Specifications 14 Warranty Information 14 Distributed by Mercola Health Resources LLC 3615 Exchange Avenue Aurora IL 60504 AIR PURIFIER Pure Clear ...

Страница 2: ... unit near a heat source open flame or flammable combustable fluids WARNING Do not operate the unit unless the following are properly installed PCO CELL PURIFICATION PLATE REAR FILTER ASSEMBLY with all three pieces in place and the REAR COVER WARNING Eye damage may result from directly viewing the light produced by the lamp inside of this unit Eye damage occurs after 20 minutes of continuous expos...

Страница 3: ...point Ionization The Pure Clear Air Purifier generates a continuous stream of millions of negative ions that circulate throughout the home These ions charge particles of dust dander bacteria and viruses causing them to attract other particles and clump together As more and more particles come together they become heavier making them easier to pull into the homes furnace filter or just fall to the ...

Страница 4: ...ode Timer HIGH FT2 PURIFIER SETTING MUST NOT EXCEED SIZE OF AREA High Mode Purifier Warning Square Footage Indicator Fan Level Indicator High mode Indicator Purifier Capacity Indicator NORMAL Normal Mode Technology Indicator Fan Level Indicator Normal Mode Indicator Control Panel Power Button Fan Control Infrared Reciever Purifier Control Normal High Toggle Reminder Reset Button Away Mode Toggle C...

Страница 5: ...oms and a laundry room The kitchen and three bedroom s doors remain open the majority of the time but the laundry room and den usually remain closed off from the rest of the house Together the laundry room and den have a combined area of 500 square feet The area of your environment would be 2000 square feet After you have established the placement of your unit and the area of the environment conne...

Страница 6: ...ONIZATION NEEDLE Disassembly Assembly Cont Assembly You will need a 1 PHILLIPS SCREWDRIVER WARNING Do not operate the unit unless the following are properly installed PCO CELL PURIFICATION PLATE REAR FILTER ASSEMBLY with all three pieces in place and the REAR COVER CAUTION The unit should be powered off and the POWER CORD should be disconnected whenever cleaning disassembling reassembling servicin...

Страница 7: ...EAR COVER CAUTION The unit should be powered off and the POWER CORD should be disconnected whenever cleaning disassembling reassembling servicing Unit Fails to Turn On 1 Verify that the POWER PLUG is plugged into an operational wall outlet 2 Ensure that the POWER CORD is properly connected to the POWER ADAPTER 3 Ensure that the POWER ADAPTER PLUG is fully seated in the receptacle on the back of th...

Страница 8: ... period as the purifier Any damages or malfunctions caused by negligence abuse or use not in accordance with the Owner s Manual are not covered by this warranty Likewise any defects or damages caused by unauthorized service or the use of other than Genuine Pure Clear Air Purifier parts are not covered Mercola com at its option repair or replace a defective Air Purifier or part s for the Air Purifi...

Страница 9: ...www GreenTechEnv com AIR PURIFIER Pure Clear Distributed by Mercola Health Resources LLC 3615 Exchange Ave Aurora IL 60504 www mercola com 847 252 4355 ...

Отзывы: