Stand Lamp_____________________________________ Order No. 3002 3012 00 
Wall Lamp ______________________________________ Order No. 3002 3021 00 
Single Ceiling Lamp______________________________ Order No. 3002 3031 25 
 

Order No. 3002 3031 30 

Ceiling Lamps  Combinations 
Emergency Power Lamp __________________________ Order No. 3002 3015 00 

 
 
 
 
 
 
 
 

Dr. Mach

 

GmbH u. Co., Flossmannstrasse 28, D-85560 Ebersberg 

Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50

 

Internet: 

www.dr-mach.com

, E-mail: 

[email protected]

 

59220001 

Edition 04 

30.07.2004 / Bak  Page 1/24 

 

Содержание Triaflex R96

Страница 1: ...__________________________________ Order No 3002 3021 00 Single Ceiling Lamp______________________________ Order No 3002 3031 25 Order No 3002 3031 30 Ceiling Lamps Combinations Emergency Power Lamp __________________________ Order No 3002 3015 00 Dr Mach GmbH u Co Flossmannstrasse 28 D 85560 Ebersberg Tel 49 0 8092 2093 0 Fax 49 0 8092 2093 50 Internet www dr mach com E mail info dr mach de 59220...

Страница 2: ...he stand Page 12 4 3 Adjustments at the lamp head Page 12 4 4 Changing of spare parts Page 13 4 4 1 Changing the halogen bulbs Page 13 4 4 2 Changing the fuses Page 14 4 4 3 Changing the filter disk Page 15 4 4 4 Changing the splinter protection disk Page 15 5 Data Page 16 5 1 Technical data Page 16 5 2 Wiring Page 17 5 3 Environmental conditions Page 18 6 Marking Page 18 6 1 Specification of bulb...

Страница 3: ...production of operating and doctor s lights Please read the safety instructions and product description carefully before working with these lights for the first time Please follow the separate mounting instructions for ceiling and wall mounted lamps and for fitting the stand foot and pipe 1 Safety instructions Please pay attention to the directions for use when handling the lamp Attention This dev...

Страница 4: ...dditional to the rocker switch 1 the customer must provide a two pole ON OFF switch see also point 5 of the mounting instructions Remark In case of Triaflex R96 lamps for power supply 24V there is no two step light intensity ad justment 2 3 Design for power supply 230 120V AC Built in toroid transformer fig B Ceiling wall model The rocker switch 2 switches the lamp ON and OFF The rocker switch 3 a...

Страница 5: ...ing and wall models For stand models this bow is not necessary Full cardanic suspension surcharge Mounting the cardan bow Mounting overview Pos 1 Cardan bow Pos 2 Securing sleeve Pos 3 Securing segment Pos 4 Securing screw M4x10 DIN 7985 Pos 5 Serrated lock washer A4 3 DIN 6798 Slide the securing sleeve pos 2 onto the cardan bow pos 1 Insert the coupling journal of the lamp bow into the receptacle...

Страница 6: ...river Slide the securing sleeve pos 2 forwards and fix it with the securing screw pos 4 and the serrated lock washer pos 5 Check the easy going movement of the lamp Stand model emergency power lamp For positioning use sterilizable handle 3 For stand models the bow of the lamp body is di rectly coupled to the bracket 5 5 5 3 59220001 Edition 04 30 07 2004 Bak Page 6 24 ...

Страница 7: ...ing of lightfields The lamps Triaflex R96 are equipped with the func tion of light field realignment That means you can merge the separated lightfields to one spot as shown in the figure To activate the merging of lightfields turn the steriliz able handle 3 59220001 Edition 04 30 07 2004 Bak Page 7 24 ...

Страница 8: ...d product specific processes are used for cleaning disinfection and that the vali dated parameters are complied with in every cycle In addition the hospital clinic hygiene regulations must be observed Cleaning disinfection Cleaning and disinfection must be carried out immediately after use A mechanised process disinfector should be used for cleaning disinfection The efficiency of the proc ess used...

Страница 9: ...placed in a suitable sterilisation pack one way sterilisation pack e g foil paper sterili sation bags single or double pack in accordance with DIN EN 868 ISO 11607 for steam sterilisation and then sterilised Use only the sterilisation procedure listed below for sterilisation Other sterilisation procedures e g ethyl ene oxide formaldehyde and low temperature plasma sterilisation are not permissible...

Страница 10: ...ning agents The splinter protection disks 3 are made of a high quality plastic Pay attention to the following during cleaning Wipe the splinter protection disks 3 always with a wet cloth Do not wipe dry Only use disinfectant with less than 20 alcohol Wipe the splinter protection disks 3 after cleaning with an antistatic non fluffy cloth 2 3 Alc 20 59220001 Edition 04 30 07 2004 Bak Page 10 24 ...

Страница 11: ...g arm with the lamp device can come to rest in any desired position A hole 1 is located at the position marked by detail X Position the spring arm 2 with the lamp device approximately 10 above horizontal Insert Allan key width 5 included in the scope of supply into the hole 1 If the spring arm drops the spring force is too low Rotate the adjustment screw to the left counter clockwise in the direct...

Страница 12: ... lamp no longer remains at its set position it may be necessary to adjust the lamp bow 4 Turn off the lamp Unscrew the raised countersunk screw 1 using a cross screwdriver Remove the upper part of the lamp housing Screw the nuts 2 on both sides a little tighter using an open ended or ring wrench SW14 or loosen these nuts while at the same time holding the screw slot 3 in each case with a screwdriv...

Страница 13: ...of the lamp housing Carefully remove the halogen bulb 2 22 8 24V 40W from its socket change and replace Replace the disk bearer onto the bottom part of the lamp housing and rotate the quick release fasteners 1 clockwise Do not touch the halogen bulb with naked hands Remove stains with a clean cloth and alcohol since otherwise these can burn into the glass and lead to early failures Attention The h...

Страница 14: ...20 1 25A 250V T for 230V Visible type 5x20 2 50A 250V T for 120V If the bulb is no longer on check the bulb first then the fuses Turn off the lamp Turn the black fuse holder 1 of a rotation anti clockwise with a screwdriver Change the fuses Insert the fuse holder 1 under slight pressure and rotate in a clockwise direction bayonet catch 1 3 2 1 3 Stand model Power supply with 230V AC The fuses 1 ar...

Страница 15: ...use of a dull splinter protection disk it may be necessary to change the disk Turn off the lamp Rotate the three quick release fasteners 1 half a turn anticlockwise so that the corresponding disk bearer can be removed from the bottom part of the lamp housing Remove the filter disk 4 as described under point 4 4 3 Loosen the three nuts 2 remove retaining spring 3 and retaining ring 5 Replace splint...

Страница 16: ...ted voltage rated current frequency Hertz fuse class of protection Power supply with 230 Volt alternating current primary side secondary side frequency Hertz fuse class of protection Power supply with 120 Volt alternating current primary side secondary side frequency Hertz fuse class of protection 59220001 Edition 04 30 07 2004 Bak Page 16 24 ...

Страница 17: ...upply with 24 Volt 22 8 24V Power supply with 230 Volt N L 0V 230V 1 23 5V 250V 1 two step switch lamps with built in transformer only Power supply with 120 Volt N L 0V 110V 1 23 5V 127V 1 two step switch lamps with built in transformer only 59220001 Edition 04 30 07 2004 Bak Page 17 24 ...

Страница 18: ...C Relative atmospheric humidity 30 75 Air pressure 700 hPa 1060 hPa Transport Storage Min Max Temperature 10 C 50 C Relative atmospheric humidity 20 90 Air pressure 700 hPa 1060 hPa 6 Marking Protective conductor Switch ON OFF 6 1 Specification of bulb Voltage power Socket Mode of operation 59220001 Edition 04 30 07 2004 Bak Page 18 24 ...

Страница 19: ...96 comply to the standards 93 42 EEC for medical products of the European Community s Council 7 Disposal The OT lamp Triaflex R96 does not contain any danger goods The components of the OT lamp should be properly disposed at the end of its shelf life Make sure that the materials are separated accordingly For disposal proceed as follows PC boards should be submitted to an appropriate recycling The ...

Страница 20: ...Triaflex R96 Ceiling Wall Stand Model Dr Mach Lamps and Engineering 8 Spare parts 8 1 Lamp head Ceiling wall stand model emergency power lamp 59220001 Edition 04 30 07 2004 Bak Page 20 24 ...

Страница 21: ...power supply for 24V do not have a built in transformer do not have fuses in the lamp head and no change over switch at the lamp head For spare parts see point 8 1 8 2 Swivel arm stand model 30 31 34 35 T1 25 A 5x20 62 63 6 4 56 60 59 65 54 53 55 61 57 58 43 59220001 Edition 04 30 07 2004 Bak Page 21 24 ...

Страница 22: ...6 19 20 3 Reflector unit complete 22060003 21 22 23 24 1 Cardan bow complete special tool 25 26 27 3 Socket with cable 67320001 28 3 Halogen bulb 22 8V 40W 67100101 29 30 1 Two pole illuminated ON OFF switch 67340002 int transformer 31 1 Change over STRONG WEAK 67340001 int transformer 32 1 Single pole ON OFF switch 67340004 ext transformer 33 34 2 Fuse holder 67370001 35 2 Visible fuse 5x20 1 25A...

Страница 23: ... 8Ni 65152010 54 2 Lock washer A4 3 DIN 6797 Zn 65582004 55 1 Brake ring 53220206 56 1 Semi circular spring 74011001 57 1 Countersunk screw DIN 966 HM3x12 4 8Zn 65112009 58 1 Housing 53220202 59 1 Sliding sleeve 53070208 60 1 Sliding contact receptacle 53223001 61 1 Sliding contact pin 53222002 62 1 Washer A8 4 DIN 125 Zn 65512008 63 2 Brake disk 53230202 64 1 Adjusting lever 74503002 65 4 Thread ...

Страница 24: ...Triaflex R96 Ceiling Wall Stand Model Dr Mach Lamps and Engineering 59220001 Edition 04 30 07 2004 Bak Page 24 24 ...