19
environments and inside tanks. They are not to be worn by firefighting
personnel.
2.
NOMINAL DURATION
The Nominal Duration for a breathing consumption of 35 litres/min (20 cycles
x 1,75 litres) is 15 minutes, according to EN 402.
3.
RELEVANT TECHNICAL STANDARDS
SEKUR NAVY MASK and SEKUR NAVY MASK 15C are III category
Individual Protective Devices according to European Regulation UE 2016/425,
certification has been issued by the
Notified Body
N. 0426 - Italcert –(Address:
Viale Sarca 336 - 20126 Milan – Italy) in compliance with EN 402 and ISO
23269-1 Standards.
SEKUR NAVY MASK and SEKUR NAVY MASK 15C are subject to the
module B+D procedures of the European Directives 2014/90/UE (Marine
Equipment), 2014/68/UE. (Pressure Equipments) and to the module D (annex
VIII) of 2016/425 Regulation. Italcert supervises the compliance of all the
indicated Directives/Regulation in D.P.I. manufacturing.
4.
TECHNICAL SPECIFICATIONS
Here below the SEKUR NAVY MASK technical features:
TABLE 1
High pressure connections
UNI EN 144/2
200 bar for SEKUR NAVY MASK and
300 bar for and SEKUR NAVY MASK
15C
Demand valve/mask connection (positive pressure)
Standard thread
M45x3 according to EN 148/3