CONTROL
MODULE WITH
FM TURNER
BLUETOOTH
CONTROL
COMMAND
INCLUDED
S 130FM
S 130 FM BT
Technical characteristics
WIRING DIAGRAM FOR S 130 FM BT CONTROL
MODULE AND UC 100 S CENTRAL UNIT
HOW TO PROGRAM THE SYSTEM:
Once all the system units are already
installed, a zone number must be assigned
to each control module as follows:
1st.- Keep the keys <> pressed during 4
seconds. The number “1” will be shown
on the displays of every control module.
2nd.- Choose the control module you
want to be the “zone 1” and press the
On/Off key. The number “1” will be
memorized as a zone number in that
control module.
3rd.- Now the rest of control modules
will show the number “2” in their displays.
Choose again which control module you
want to be the “zone 2” and press the
On/Off key of that module.
4th- Repeat the process as many times
as control modules/zones are in the
installation.
5th- Once the zone assignment is finished,
keep the control module on/off key
pressed during 4 secondsin order to leave
the “assingnment zone mode”.
NOTE.-
The
UC 100 S
supports a
máximum of 10 sound control modules and
a maximum distance of 100 mts.of cable to
the last element to be controlled. For higher
installations, power supply units or a more
powerful central unit would be required.
System with power supply unit
0
5
-
+
+
-
R+ R- L- L+
0 5 8 9
C1L C1R
MAINS 230 Vac.
2x0,75 mm.
0
5
8
9
-
+
+
-
C1L
C1R
R+ R- L- L+
0 5 8 9
C1L C1R
S 130 FM BT
UC 100 S
System with central unit
For AUXILIARY CONNECTION of audio, TV, PC, etc. please
use 0 (ground) and C1L and C1R (Left and right channel 1)
M
M
M
ANT
ANTENNA CONNECTION:
Conductor wire
of 80 cm. In zones of bad reception, connection
to outdoor antenna it is highly recommended.
0
5
8
9
M
C1 R
C1 L
B
GROUND -Vcc
POWER SUPPLY 12 +Vcc
COMUNICATIONS
COMUNICATIONS
MICROPHONE AUDIO
RIGHT CHANNEL 1
LEFT CHANNEL 1
AUDIO RETURN
=
=
=
=
=
=
=
=
S o u n d & H o m e
A u t o m a t i o n
STEREO
ZONE
CABLE REF. W-2
MINIMUM SECTION
2X0.50 MM
Speaker
Ref. SP 5
STEREO
ZONE
CABLE REF. W-2
MINIMUM SECTION
2X0.50 MM
Speaker
Ref. SP 5
doyson.com
Nr. of channels...................................1 stereo channel
Amplifier..............................................1.5+1.5W stereo
Bluetooth............................................A2DP transmission protocol
Minimum load impedance................8 ohms
Power supply......................................12Vcc/330mA
Stand-by power consumption........25mA
Operational power consumption..69mA
Connectors.........................................Strip terminals
Dimensions.........................................44 x 44 x 36mm depth
CABLE REF. W-8
MINIMUM SECTION
2X1 MM
6x0.25 MM
MAINS
100-240 Vac.
FA 12 BI
Power supply
unit
BACKLIT LCD SCREEN: On/Off, alarm clock,
FM radio, mono/stereo, auxiliary audio input,
FM signal level, radio station frequency and clock
icons.
ON/OFF KEY: Automatic control of central
unti built-in socket. AutoOn and autoOff set up.
CONTROL KEYS: Volume, bass, treble,
mono/stereo… FM scan and memory
selection… Zone call selector…
MOD MAIN MENU KEY: Function selection:
volumen, bass, treble, balance, auto on/off…
FM/CH FM SCAN KEY. BLUETOOTH.
CHANNEL 1 and AUX. IN.
MIC GENERAL AND ZONE CALL KEY:
Short push for general calls. Long push for zone
calls using <> keys for zone selection
MICROPHONE
AUXILIARY AUDIO INPUT