background image

Содержание 2045 series

Страница 1: ...c 1987 I INSTRUCT IO j DOVETEC HEATING SYSTEM FIREPLACE INSERT AND FREESTANDING STOVE FEATLTRE Preparation Installation Operation Maintenance Safety BUCKNER ENTERPRISES CORPORATION 1987 U L LISTED STA...

Страница 2: ...g efficiency from your unit By following these instructions and suggestions you can be assured years of safe arid economical heating for yourself and your family THANK YOU for buying a DOVETEC If this...

Страница 3: ...rotection For you to realize all the advantages of the reliable service that have been engineered into your DOVETEC you must follow all the instructions contained in this book Before attempting to ins...

Страница 4: ...anel B II FREESTANDING INSTALLATION 10 MinimumClearances Installation 12 Section III MOBILE HOME OR PRE MANTJFTCTURED HOMES 13 Section I V SAFETY 1 4 Section V OPERATION 16 Final Check 16 Ignition Shu...

Страница 5: ...ower Double blower unit developing 320 CFM of air circulating through your home Takes the cool room air into the unit heats it then expells it thereby heating your home 10 Combustion Air Blower Suppli...

Страница 6: ......

Страница 7: ...e floor protector must measure a minimum of 40 xlZ The floor protector must be constructed of non combustible inorganic material equal to one layer of 3 8 thick miliboard having a thermal conduc tivit...

Страница 8: ...on to the stove bottom If it is determined that the stove will block the trap door then the unit must be raised approximately 1 2 inch to allow fresh combustion air to enter the fireplace area and to...

Страница 9: ...ach a 3 diameter stainless steel flex tubing to the exhaust pipe on the rear of the unit long enough to reach the smoke shelf through the damper opening b Slide the adapter box over the flue end of th...

Страница 10: ...lieore cement along the heck edge of the trim panel as shown in Figure 5 Make sure all cracks or openings along the back edge where the trim panel and the stove ioin are cemented 4 Place the fiberglas...

Страница 11: ...ombustih1e pad if the floor of the house is of combustible material The pad mast meet the following minimum specifications 1 a UL Listed floor protector or a floor protector riade of a non combustible...

Страница 12: ...H RDIE 4EtDED 49 O Erackets 2_1l x 3 8 Leg Screws 4 1w x 10 32 Bolts 4 o 10 Washers 4 10 32 Nut 2_1016_3 4v Tec Screws FWURE 12...

Страница 13: ...IGURES H Iliri Clearance Rainshield 1 Intake Zero Clearance Figure 8 Fiur 9 4 Mm Clearance to Combustibles Floor Protector Page 11...

Страница 14: ...the pipe as it is desjgned and UL Listed for zero clearance 3 After proper fit of the pipe has been accomplished nove the DOVETEC back into position 41 From the outside of the home push the pipe thro...

Страница 15: ...ion Use two 90 degree L brackets from your kit and anchor to the floor using 1 leg screws Drill a 1 4 hole through the base and secure the brackets to the base using two of the 10 32 bolts 10 washers...

Страница 16: ...d the unit as well as in sleping areas halls etc 7 Always keep a fire eting iisher rated for class A fires near the unit 6 Check with your insurance company to be sure your policy covers the use of a...

Страница 17: ...start or freshen up a fire Keep all such flazTriable liq iids well away from the unit while in use 2 Burn the unit without the burner in place 3 Try to burn paper Attempt eectrical repairs 5 Leave sm...

Страница 18: ...properly grounded 115V 1C receptacle Turn timer setting to a high position recommended time on 5 off 5 L Open door and fill burner box with wood pellets approximately one inch below top edge of box 5...

Страница 19: ...n blower which forces air into the burner box and draws the exhaust out of the firebox WARM AIR CIRCUIJLTION BLOWER CONTROL Controls the amount of warm air entering the room This control regulates the...

Страница 20: ...stion blower switch HELPFtSL HINTS 1 Clean the outside surface of your DOVETEC with a damp cloth 2 Clean the glass with a dry soft cloth Most of the time glass cleaner is not needed since there is lit...

Страница 21: ...ure to unplug the power supply cord before lubricating The seal between the fireplace masonry and the unit as well as the seals on the unit itself should be checked and resealed if there is evidence o...

Страница 22: ...od pellets or shelled corn the glass may cloud up with a fine powder of ash Wipe it clean with a dry cloth 3 Check the gasket around the glass Replace if needed FILTER SCREEN MAINTENANCE 1 Unplug unit...

Страница 23: ...option any part defective in materials or worJoanship affecting the operation of the heating system The coat of parts only are included The customer pays any labor or transportation charges 8 Period I...

Страница 24: ...een to be sure that no foreign matter exists WARRANTY DISCLAIMER REGARDING FUEL The expressed written warranty on the DOVETEC CORN HEATER does riot cover damage to the stove or clogging of the feed sy...

Страница 25: ...ty applies only to parts or conponents which are defective and does not cover repairs necessaxy due to normal wear misuse accident or lack of proper maintenance OTHER RIGHTS This warranty gives you sp...

Отзывы: