Dover WILDEN PRO-FLO P1 Series Скачать руководство пользователя страница 1

EOM-P1P 10/03

TT4139

Replaced EOM-P1P 5/03

Содержание WILDEN PRO-FLO P1 Series

Страница 1: ...EOM P1P 10 03 TT4139 Replaced EOM P1P 5 03...

Страница 2: ...A 8 SECTION 7 INSTALLATION OPERATION A Installation 9 B Operation Maintenance 10 C Troubleshooting 11 SECTION 8 DIRECTIONS FOR DISASSEMBLY REASSEMBLY A Model P1 PLASTIC Wetted Path Tools Required Torq...

Страница 3: ...ith integral piston White VT VITON Silver or White Dot WF WIL FLEX Orange VALVE BALL BN BUNA N Red Dot FG SANIFLEX Cream PU POLYURETHANE Brown TF TEFLON PTFE White VT VITON Silver or White Dot WF WIL...

Страница 4: ...amber and manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the...

Страница 5: ...ics CAUTION Before any maintenance or repair is attempted the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from pump Disconnect all intake discharge and...

Страница 6: ...TANDARD inch A 224 8 8 B 25 1 0 C 133 5 2 D 216 8 5 E 231 9 1 F 53 2 1 G 25 1 0 H 114 4 5 J 140 5 5 K 203 8 0 L 8 0 3 M 8 3 3 N 104 4 1 P 117 4 6 R 147 5 8 S 25 1 0 SECTION 4B DIMENSIONAL DRAWING WILD...

Страница 7: ...226 8 9 B 23 0 9 C 132 5 2 D 213 8 4 E 229 9 0 F 25 1 0 G 132 5 2 H 56 2 2 J 114 4 5 K 201 7 9 L 8 0 3 M 76 3 0 N 102 4 0 P 114 4 5 R 142 5 6 FOR BONDABLE TEE SECTION S 83 3 3 All P1 Ultrapure pumps a...

Страница 8: ...e pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve SECTION 5B PERFORMANCE CURVES WILDEN P1 PLASTIC TPE FITTED Height 218 mm 8 6 Width...

Страница 9: ...mps should be specified so that daily operation parameters will fall in the center of the pump performance curve SECTION 5D PERFORMANCE CURVES MODEL P1 PLASTIC CARBON FILLED ACETAL Height 231 mm 9 1 W...

Страница 10: ...3 h 3 9 scfm air consumption See dot on chart Caution Do not exceed 8 6 bar 125 psig air supply pressure Flow rates indicated on chart were determined by pumping water For optimum life and performance...

Страница 11: ...ance ELEVATION Selecting a site that is well within the pump s dynamic lift capability will assure that loss of prime troubles will be eliminated In addition pump efficiency can be adversely affected...

Страница 12: ...ould be made of all necessary repairs and replacements Over a period of time such records can become a valuable tool for predicting and preventing future maintenance problems and unscheduled downtime...

Страница 13: ...hift 7 Remove plug from pilot spool exhaust Pump runs but little or no product flows 1 Check for pump cavitation slow pump speed down to allow thick material to flow into the liquid chambers 2 Verify...

Страница 14: ...8 lpm 15 gpm The single piece center section consisting of center block and air chambers is molded of polypropylene or acetal All fasteners and hardware are stainless steel and the air valve is manuf...

Страница 15: ...gouges chemical attack or abrasive wear Replace worn parts with genuine Wilden parts for reliable perfor mance Teflon o rings should be replaced when reassem bled Figure 5 Step 6 Figure 6 Normally th...

Страница 16: ...mbly can be removed from the center section Figure 11A Step 11B Figure 11B 2 The outer piston diaphragm inner piston and disc spring separate from the shaft which remains connected to the opposite sid...

Страница 17: ...ed Viton on the UPII and carbon filled acetal and Chemraz on the UPIII The standard air distribution system is used on the UPII All o rings used in the pump are of a special mater ial and should only...

Страница 18: ...3 Figure 3 Remove the o ring ball cage and ball valve from the water chamber It is now possible to inspect these parts see Figure 3 Using the o ring pick remove the seat and seat o ring from the wate...

Страница 19: ...ny maintenance or repair is attempted the compressed air line to the pump should be discon nected and all air pressure allowed to bleed from the pump Disconnect all intake discharge and air lines Drai...

Страница 20: ...ports cut in the sleeve NOTE Seals should not be removed from pilot spool Seals are not sold separately Step 9 Figure 9 Check center section Glyd rings for signs of wear If necessary remove Glyd rings...

Страница 21: ...is is most easily accomplished by placing them on a flat surface prior to tightening their clamp bands to the desired torque see this page for torque specs Be sure to tighten outer pistons simultaneou...

Страница 22: ...ts P N 01 9501 99 for all seal ing surfaces P1 Poly and Carbon filled acetal pumps come standard with expanded Teflon Gasket Kits P N 01 9500 99 for diaphragm bead only Carefully prepare sealing surfa...

Страница 23: ...21 WILDEN PUMP ENGINEERING LLC NOTES...

Страница 24: ...22 WILDEN PUMP ENGINEERING LLC SECTION 9A EXPLODED VIEW PARTS LISTING P1 PLASTIC RUBBER FITTED...

Страница 25: ...6802 08 17 Inner Piston 2 01 3711 08 01 3711 08 18 Outer Piston 2 01 4570 20 500 01 4570 20 500 19 Liquid Chamber 2 01 5000 20 01 5000 21 20 Manifold Tee Section 2 01 5160 20 01 5160 21 21 Inlet Mani...

Страница 26: ...24 WILDEN PUMP ENGINEERING LLC SECTION 9B EXPLODED VIEW PARTS LISTING P1 PLASTIC TEFLON FITTED...

Страница 27: ...000 20 01 5000 20 01 5000 21 01 5000 21 01 5000 22 20 Manifold Tee Section 2 01 5160 20 01 5160 20 01 5160 21 01 5160 21 01 5160 22 21 Inlet Manifold Elbow 2 01 5220 20 01 5220 20 01 5220 21 01 5220 2...

Страница 28: ...26 WILDEN PUMP ENGINEERING LLC SECTION 9C EXPLODED VIEW PARTS LISTING P1 PLASTIC ULTRAPURE...

Страница 29: ...all Cage 2 01 5350 22 520 01 5350 22 520 01 5350 16 01 5350 16 21 Inlet Manifold Elbow 2 01 5080 22 520 01 5080 22 522 01 5080 16 01 5080 16 22 Discharge Manifold Elbow 2 01 5020 22 520 01 5020 22 522...

Страница 30: ...01 1300 582 Saniflex 01 1010 56 01 1080 56 N A 01 1200 56 01 1300 56 Teflon PTFE3 01 1010 55 01 1080 55 01 1120 22 500 N A N A Teflon PTFE 01 1030 55 N A N A N A N A with integral piston PVDF N A N A...

Страница 31: ...ng warranty is exclusive and in lieu of all other warranties expressed or implied whether written or oral including all implied warranties of merchantability and fitness for any particular purpose No...