![Dover Wilden Advance Pro-Flo V PV400 Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/dover/wilden-advance-pro-flo-v-pv400-series/wilden-advance-pro-flo-v-pv400-series_engineering-operation-and-maintenance_2525057016.webp)
WILDEN PUMP & ENGINEERING, LLC
14
WIL-11100-E-05
S e c t i o n 5 B
S U C T I O N L I F T C U R V E S
Suction lift curves are calibrated for pumps operating
at 305 m (1,000') above sea level. This chart is meant
to be a guide only. There are many variables which
can affect your pump’s operating characteristics. The
number of intake and discharge elbows, viscosity of
pumping fl uid, elevation (atmospheric pressure) and
pipe friction loss all affect the amount of suction lift
your pump will attain.
P 4 0 0 A L U M I N U M
S U C T I O N L I F T
C A P A B I L I T Y
P 4 0 0 S TA I N L E S S S T E E L
& A L L O Y C S U C T I O N
L I F T C A P A B I L I T Y