Dover PSG Mouvex CENTREX MULTI 2M Скачать руководство пользователя страница 1

INSTALLATION

OPERATION

MAINTENANCE

2M version (Meter)

2ME version (Electronic Meter)

2T version (Turbine)

INSTRUCTIONS 1006-C00 e

Section          1006

Effective        March 2018

Replaces       March 2017

Original instructions

CENTREX MULTI 2

Version 3

Your distributor :

Z.I. La Plaine des Isles - F 89000 AUXERRE - FRANCE

Tel. : +33 (0)3.86.49.86.30 -  Fax : +33 (0)3.86.49.87.17

[email protected]  -  www.mouvex.com

WARRANTY :

CENTREX MULTI 2 units are covered 24 months by warranty within the limits mentioned in our General Sales Conditions. 
In case of a use other than that mentioned in the Instructions manual, and without preliminary agreement of MOUVEX,
warranty will be canceled.

Содержание PSG Mouvex CENTREX MULTI 2M

Страница 1: ...Version 3 Your distributor Z I La Plaine des Isles F 89000 AUXERRE FRANCE Tel 33 0 3 86 49 86 30 Fax 33 0 3 86 49 87 17 contact mouvex com www mouvex com WARRANTY CENTREX MULTI 2 units are covered 24 months by warranty within the limits mentioned in our General Sales Conditions In case of a use other than that mentioned in the Instructions manual and without preliminary agreement of MOUVEX warrant...

Страница 2: ... MOUVEX CENTREX MULTI 2 units must ONLY be carried out by qualified technicians This maintenance must meet local and national standards as well as all safety regulations Read this manual including all instructions and warnings in full BEFORE any use of MOUVEX CENTREX MULTI 2 units Do not remove the warning and use label stickers that are found on the compressors ADDITIONAL DOCUMENTATION The table ...

Страница 3: ...den crosspieces after installation Fork zone WARNING PUMPS OPERATING AGAINST A CLO SED VALVE CAN CAUSE SYSTEM FAILURE PERSONAL INJURY AND PROPERTY DAMAGE Hazardous pressure can cause personal injury or property damage WARNING OPERATION WITHOUT THE SHAFT PROTECTOR CAN CAUSE SERIOUS PERSONAL INJURY MAJOR PROPER TY DAMAGE OR DEATH Do not operate without guard in place WARNING DISCONNECTING THE FLUID ...

Страница 4: ...ENTREX MULTI 2 T 0 7 0DQRPHWUH 3UHVVXUH JDXJH 9LVHXU 6LJKW JODVV FKHFN SRXU DQFUDJH 0 IRU DQFKRUDJH 0 ULGH ODQJH 6 DO RX RU 2SWLRQ YDQQH YRLHV 7XEH j VRXGHU 237 21 PHWWHXU 62 RX HPHWWHXU 9HHGHU 5RRW 0RWHXU 7 9 RX 7 N 3 3LHG UpJODEOH GMXVWLQJ IRRW 3XUJH UHWRXU SURGXLW UDLQ 5 6 1 DYHF ERXFKRQ 6QDS FRXSOLQJ 1 ZLWK SOXJ 237 21 PSULPDQWH 3ULQWHU 5HWRXU GpJD DJH HJDVVLQJ UHWXUQ OLQH RSWLRQ 0 7 RPSWHXU 0...

Страница 5: ...signals depending on the version Once the compartment is empty the assembly will fill with air and the meter will stop If the next compartment contains the same product connect the DN80 hose to it without stopping the pump If the next compartment contains another product Lift the DN80 hose to drain it and wait for the meter to stop and the gas separator sight glass 17 to empty Print the ticket wher...

Страница 6: ...to zero 2 2 Operating characteristics Nominal flowrate 60 m3 h Maximal differential pressure 4 bar Maximum vacuum allowed 0 3 bar Running temperature 10 to 50 C The noise generated by the CENTREX unit under normal operating conditions 80 dBA Minimum delivery 500 litres Accuracy of the metering unit 0 4 Repeatability 0 05 2 3 Operation The operator should remain nearby the equipment through out the ...

Страница 7: ...ULTI Turbine version is delivered with the discharge piping module disconnected That allows to reduce the dimensions and in consequence to mini mize the packaging size This module has to be connec ted already tested in our workshop please make sure the pipe is properly supported in order to avoid any vibrations creation as well tension on the unit We recommend placing valves as close as possible t...

Страница 8: ...st be protected by appropriate circuit breakers and fuses Connect the regulatory ground connections Check the direction of rotation This check should be done with no product being pumped and both the inlet and discharge circuits vented to avoid generating unexpected pressure on the inlet side for example This will avoid damaging either the pump or the system WARNING OPERATION WITHOUT THE SHAFT PRO...

Страница 9: ...E OPERATION Toxic or hazardous fluids can cause serious injury 5 PRODUCTS UNLOADED Start the pump empty to check that the connections are good and that the direction of rotation corresponds to the system intake and discharge directions If it is necessary to reverse the direction of rotation follow the instructions below Three phase motor switch any 2 current input wires Ensure to remove the draini...

Страница 10: ...ORK IMPOSSIBLE Any unforeseen start up can cause serious injuries or important material damages WARNING BE CAREFUL WITH THE WEIGHT OF THE PARTS WHEN THEY ARE BEING REMOVED The weight ot the parts can be dangerous and may provoke bodily injuries or material damages WARNING HYDRAULIC PRESSURE MUST BE FULLY RELEASED BEFORE MAINTENANCE OPERATIONS IN ORDER TO PREVENT PERSONAL INJURY OR PROPERTY DAMAGE ...

Страница 11: ...ngen bezogen auf mechanische und elektrische Risiken die für rotierende Maschinen gelten NF EN 809 2009 NF EN 1672 2 2009 NF EN ISO 13857 2008 NF EN 12162 2009 ATEX Richtlinie 2014 34 EU 26 Feb 2014 wie umgesetzt im nationalen Recht in Bezug auf Ausrüstungen für den Einsatz in explosionsgefährdeter Atmosphäre Die Konformität hat Geltung durch Anwendung folgender Normen NF EN 1127 1 1997 NF EN 1346...