Dover MOUVEX A10 Скачать руководство пользователя страница 1

PUMPS A10 - AS10

INSTALLATION

OPERATION

MAINTENANCE

INSTRUCTIONS 1101-A00 e

Section

1101

Effective

September 2011

Replaces

October 2010

Original instructions

Your distributor :

Z.I. La Plaine des Isles - F 89000 AUXERRE - FRANCE

Tel. : +33 (0)3.86.49.86.30 -  Fax : +33 (0)3.86.49.87.17

[email protected]  -  www.mouvex.com

3, Poruchik Nedelcho Bonchev Str., fl. 5

1528 Sofia, Bulgaria

tel: +359 2 973 27 67

e-mail: [email protected]

Содержание MOUVEX A10

Страница 1: ...ember 2011 Replaces October 2010 Original instructions Your distributor Z I La Plaine des Isles F 89000 AUXERRE FRANCE Tel 33 0 3 86 49 86 30 Fax 33 0 3 86 49 87 17 contact mouvex com www mouvex com 3 Poruchik Nedelcho Bonchev Str fl 5 1528 Sofia Bulgaria tel 359 2 973 27 67 e mail office daisglobal eu ...

Страница 2: ...alert to the potential for personal injury death or major property damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major property damage Warns of hazards that CAN cause personal injury or property damage NOTICE Indicates special instructions which are very important and must be followed ...

Страница 3: ...3 16 NT 1101 A00 09 11 A10 AS10 e 1 1 A10 model 1 OVERALL DIMENSIONS speed Thermal sensor emplacement to choose according rotation direction see ATEX Instructions Pump plate S P ...

Страница 4: ...6 NT 1101 A00 09 11 A10 AS10 e 1 2 AS10 model 1 OVERALL DIMENSIONS continued Thermal sensor emplacement to choose according rotation direction see ATEX Instructions Pump plate S P shaft end detail 4 holes ...

Страница 5: ...al and precise directions However we recall that it is never prejudicial to plan for wide piping diameters particularly regarding the intake For the discharge it is also possible to plan for a diame ter equal to that of the pump s orifices and on the inta ke for a wider diameter if suction is very strong In the case of viscous products the determination of this dia meter is very important since th...

Страница 6: ...aterial rotation speed temperature etc In order for the pump to generate the normally required flow MOUVEX recommends using a vacuum draw kit inside the body of the pump In all cases when using a vaccum kit suction pressure must not be lower than 0 9 barg 13 psig If a vacuum draw kit is not used on an ABAQUE pump operating with suction pressure lower than atmospheric pressure MOUVEX no longer guar...

Страница 7: ...any product with the inlet and outlet circuit open to the air for example to avoid any risk of an unexpec ted pressure rise Start the pump empty to check the cor rect operation of the connections and check that the direction of rotation corresponds to installation s inlet and outlet direction Follow the instructions below if necessary to change the direction of rotation Three phase motor switch an...

Страница 8: ...to ensure that the consistency of the deposi ted products will not affect the start up of the pump 3 5 Starting up the pump Before starting up the pump always ensure that the pum ping conditions are correct with the corresponding valves open especially the inlet valve For use at temperatures below 0 C 32 F specific pre cautions must be taken Refer to LUBRICATION 3 6 Shutting down the pump When shu...

Страница 9: ...OTES To insure an optimal life cycle of the hose it is recom mended to replace the worn lubricant by some new lubricant during any replacement of hose The hose may contain a certain volume of the pumped fluid but this will be expelled when restarting the pump Evacuation of this fluid may also be carried out by run ning the pump after having taken all the safety measu res required for personal and ...

Страница 10: ...dy 1 with screws 33 and washers 34 WARNING Do not operate without guard in place NEVER INSERT THE HOSE OR RUN THE PUMP WITHOUT ITS COVER AND ITS WIN DOW IN PLACE NOTE Moderately tighten screws so as not to crack the transparent plate of the cover Once the screws are tightened the seal must be squeezed all over NOTE If the pump is not re assembled immediately dry unpainted surfaces and coat them wi...

Страница 11: ...screw it on the body using screws 48 and washers 49 Fit snap ring 24 in the groove provided for this purpose on the insert Appropriately tighten clamp 7 on hose boot 6 Make sure that it is not cut 7 take care on the direction of assem bly of the hose clamp it must be directed so that the part presenting a lively fish bone is side body Tighten clamp 9 more tightly on boot 6 and hose 16 When startin...

Страница 12: ...cone Remove the wheel 3 by sliding it along the central axis 4 2 2 ASSEMBLING THE WHEEL Check the shaft seal 26 Replace when necessary making sure that it is assembled so that the spring can be seen inside the pump body Check that the wheel have no dents or deep scratches that may quickly dereriorate the hose Insert the parts of the hub 19 in the wheel center Slide wheel 3 with its hub 19 on the a...

Страница 13: ...x service 50 C Max service 60 C Max service 70 C Max service 80 C 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 10 20 30 40 50 60 70 80 90 Rotation speed rpm Motor power kW 0 2000 4000 6000 8000 10000 12000 14000 0 02 0 03 0 05 0 06 0 08 0 09 0 11 0 12 0 14 Flowrate m3 h Max viscosity cps 3 bar 5 bar 8bar Coutinuous service Intermittent service Max service 122 F Max service 140 F Max service 158 F Max service...

Страница 14: ...shed with a cleaning agent that is compatible with the hose material and the pumped product It is recommended that the hose be monitored so that it can be replaced before any breakdown should occur Preventive replacement is advisable Temperature threshold values for the liquid pumped depend directly on the materials that make up the hose Refer to technical characteristics on the cover page for the...

Страница 15: ...sure drop at inlet Check the inlet line see 2 4 PIPE DIAMETERS WEAK FLOW The pump hose is damaged Replace the hose see 4 1 REPLACING THE HOSE The lubricant is not suitable Empty the pump body and replace the lubricant with one that is recommended by MOUVEX The lubricant is dirty or too old Empty the pump body and replace the lubricant with a new MOUVEX lubricant Temperature of the pumped fluid is ...

Страница 16: ...Max T Flow 80 C is in conformity with the provisions of the following Directive x ATEX Directive 94 9 EC 23 march 1994 as transposed by the national legislation concerning equipment intended to be used in explosive atmospheres Conformity obtained by application of the standards NF EN 1127 1 1997 NF EN 13463 1 2009 NF EN 13463 5 2009 ATEX Certification delivered by INERIS Notified Body INERIS Parc ...

Отзывы: