![Dover Anthony Complete 101 Series Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/dover/anthony-complete-101-series/anthony-complete-101-series_installation-manual_2524816040.webp)
Complete 101 Series Installation Manual
99-25517-I001 July 2022 Rev. B
39 |
P a g e w w w . a n t h o n y i n t l . c o m
Section 5 - Required Functionality for Complete Install
The following items must be functional for the installation to be completed and closed out:
Door Frame Assembly
Door/frame assembly should be in proper alignment and level/plumb.
Gasket
The gasket must be properly sealed and touch the contact plate around the entire door assembly. The gasket must not be rolled or torn.
After handling the door during installation, the door gaskets may be pulled out of the door rail dart, to ensure optimal sealing between the
door gasket and frame you must check that gaskets are properly seated in the door. To re-install the gaskets, “Gasket Check” section in
“
Section 4 – Door Installation”
.
Hinge Pin
Three (3) grams of a high viscosity dielectric grease must be applied to the Hinge Pin receptacle at the time of installation. For installations
where doors are in Harsh and/or Extreme ambient conditions with excessive moisture, it is recommended to use a minimum of 3 grams of
Anthony P/N: 98-25497-0001 dielectric grease to fill the holes in the Hinge Pin receptacle socket. This will prevent corrosion and other issues
excessive moisture can cause.
Hold Open Assembly
Hold open bolt must be in good working order, not broken, bent, or stripped. Hold open bracket must be functional and properly hold the
door in the open position when open completely and engaged.
Torque Master Assembly
Torque Master assembly must be properly adjusted and functioning to close the door when it is held partially open
(6 Inch test) When the installer lets go of the handle, the door should close completely without any pressure from the installer.