To Enable Password Protection
Press and Hold,
then press Reset button once,
keep holding till LED goes ON.
BLUE
WHITE
24VAC POWER
To Disable Password Protection
Press and Hold,
then press Reset button once,
keep holding till LED goes ON.
Whichever LED is ON indicates
password protection state.
Group ON/OFF
Use to test.
Button actuates
a preprogrammed
relay group.
Relay Group #
ON=Single Command / Call
OFF=Multiple Command / Call
Tones allowed
during voice prompts
ON=Relay Group Control
OFF=Relay Control
Device Status
Pressing Reset Button
will cause a software
reboot of the WTI-2332.
Blinking= OK
Reset
On Hook
Ring
USB
Telephone
Line
LED ON
when USB
connected
www.DouglasLightingControl.com
WTI-2332-FT
Telephone Interface
EARTH
NET B
NET A
Service
Wink
Lonworks
FTT-10 Signal
Technical Data
WTI-2332-FT
Telephone Interface
www.DouglasLightingControls.com
n
The WTI-2332-FT Telephone Interface
allows users to access the Douglas lighting
control network from a standard touch-tone
phone.
n
The WTI-2332-FT can also be integrated
into an external Lonworks control system.
n
Phone plugs directly into the RJ11 port
on the unit.
n
Using simple telephone key commands,
the user can select a relay group, check
its status, and turn it ON or OFF.
n
Voice prompts are provided for ease and
simplicity of operation. Voice prompt
responses give the user confirmation of
each command.
n
Can be password protected.
n
Automatic disconnect after several seconds
of user inactivity or when user hangs up.
Connections
n
Power:
24VAC, 100mA.
n
LonWorks Data Signal: FTT-10 (78kbs)
standard LonTalk data signal.
n
Telephone: dedicated line from touch-
tone phone to built-in modem port.
Operation
n
WTI-2332-FT accessed by dialing
telephone number provided by system
administrator. Dialing must be paced
and deliberate.
n
Upon connection, password can be
required and is entered with telephone
keypad.
n
Telephone command, entered with
telephone keypad, consists of function
code (ON, OFF or status), group (or
individual relay) number, and
initiation code.
n
Voice prompts provided by system.
Network Technology Specification
n
LonWorks
®
technology.
Environment
■
Indoors, stationary, non-vibrating,
non-corrosive atmosphere and
non-condensing humidity.
n
Ambient operating temperature:
-0°F to +120F (-15°C to +50°C).
PART No.
SPECIFICATION
DESCRIPTION
DIMENSIONS & MOUNTING
WTI-2332-FT Telephone Interface
Data Signal
Connect network data signal here.
LonWorks Network: wiring is 16AWG twisted pair, non-polarized,
unshielded, stranded or solid.
RJ11 Jack
Connect the telephone
line here.
Wink Button and LED
LED flashes when network
Wink
command received.
Press button to clear
Wink
command.
Service Button & LED
Press button to identify unit to
network for diagnosis.
Flashing LED indicates
defective unit.
Reset Button
Press and hold at startup
to restore defaults.
n
Telephone Interface mounts to 35mm
DIN rail installed in relay panels.
Unit shipped with DIN mounting rail.
WTI-2332-FT
Telephone
Interface
Power Terminals
Connect to 24V transformer
in panel.
Group Test Button
Press button to toggle pre-
selected group ON and OFF.
Power Indicator LED
Flashes when unit
receiving power.
Ring LED
Flashes when call is
being sent.
Telephone Online
Indicator LED
ON if modem is active.
USB Port and LED
Connect USB from pc here for
using the pc hyperterminal to
configure the unit.
LED flashes when pc is connected
and a signal is being transmitted.
6.5"
(165)
1.75"
(45)
Plan View
Side View
6.5"
(165)
4.0"
(103)
WTI-2332-FT
Telephone Interface
DIP Switches
Factory Setting is all
3 switches in ON
(right) position:
#1 ON (single command per
session).
#2 ON (can enter command
during prompt).
#3 ON (relay groups activated).
#1 OFF (multiple commands per
session).
#2 OFF (cannot enter command
until prompt ends).
#3 OFF (individual relays
activated).
1
2
3
ON
OFF
Password
Activate/Disable
Buttons and LEDs
Press and hold the
password activate -
disable button. Then
press Reset button once.
Keep holding the
password activate or
disable button until
the LED goes ON.