Single Port N
ODE
Ethernet to DMX Interface Configuration &
Owner’s Manual
model: N
1-A, N
1-P
Doug Fleenor Design, Inc. 396 Corbett Canyon Road
Arroyo Grande, CA 93420
(805) 481-9599 Voice and FAX
Manual Revision November 2021
Страница 1: ...NODE Ethernet to DMX Interface Configuration Owner s Manual model NODE1 A NODE1 P Doug Fleenor Design Inc 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Voice and FAX Manual Revision Nov...
Страница 2: ...portable version also uses a rugged Ethercon connector for its Ethernet connection DMX PORT SPECIFICATIONS Port circuit EIA 485 transceiver with 120 ohm termination between Data and Data NOTE This pr...
Страница 3: ...installation and wiring space Care must be taken to insure that no part of the electronics are touching the box Do NOT attempt to install the NODE1 A while power is applied If necessary protect the N...
Страница 4: ...r network interface such as an Ethernet switch or computer 3 DMX LED When the DMX512 port is configured as an output the DMX LED illuminates when the NODE1 is receiving network data on its configured...
Страница 5: ...o 255 0 0 0 Before deploying the NODE1 into the field it is recommended that each NODE1 is connected to an isolated network for configuration This will allow configuration while the computer and the N...
Страница 6: ...ess Subnet Mask MAC Address DMX512 port Universe selection and DMX512 port input output status are shown A menu bar at the top of the page has links to access the network settings and the DMX512 port...
Страница 7: ...Settings button on the bottom right of the page before navigating away from this page If another page is selected before saving all changes will be lost If the IP Subnet or DHCP settings have been ch...
Страница 8: ...done automatically Six network sources per port are allowed on the NODE1 This means that a single port on the NODE1 set for universe one can automatically merge six different sources which are generat...
Страница 9: ...has the same subnet mask and that each unit has a unique IP address in that subnet The NODE1 comes from the factory with a static IP in the range of 10 X X X which is based on its MAC address Note th...
Страница 10: ...5 0 0 0 These must be followed for the NODE1 to inter operate completely with other Artnet Gear 6 If there will be more than 100 network universes in a connected network a managed Layer 3 network shou...