34
Alphabetical list of commands
clear expander-status
Description
Clears the counters and status for SAS expander lanes. For use by or with direction from technical
support.
Counters and status can be reset to a good state for all enclosures, or for a specific enclosure whose
status is
Error
as shown by the
NOTE:
If a rescan is in progress, the clear operation will fail with an error message saying that an
EMP does exist. Wait for the rescan to complete and then retry the clear operation.
Min. role
manage
Syntax
clear expander-status
[enclosure
ID
]
Parameters
enclosure
ID
Optional. The enclosure number. If this parameter is omitted, the command clears the counters and
status of all enclosures.
Example
Clear the expander status for the enclosure with ID
1
.
# clear expander-status enclosure 1
See also •
Содержание AssuredSAN 6004
Страница 11: ...Document conventions and symbols 11 TIP Provides helpful hints and shortcuts...
Страница 58: ...58 Alphabetical list of commands exit Description Log off and exit the CLI session Min role monitor Syntax exit...
Страница 107: ...set led 107 Identify drawer 1 in enclosure 1 set led drawer 1 1 on Identify fan 1 in enclosure 1 set led fan 1 1 on...
Страница 114: ...114 Alphabetical list of commands See also set cli parameters show protocols...
Страница 139: ...show controller statistics 139 See also reset all statistics reset controller statistics...
Страница 153: ...show disk statistics 153 See also reset all statistics reset disk error statistics reset disk statistics show disks...
Страница 162: ...162 Alphabetical list of commands See also show power supplies...
Страница 207: ...show volume reservations 207 Basetypes volume reservations status See also release volume show volumes...