background image

 

Installation manual 

trovan

 

Access Guard

 

 
 
 

 

 
 

 

 

DATE: 5 November 2008 

 

Copyrights: 

DORSET 

IDENTIFICATION B.V.

 

The Netherlands 

Tel. +31 543 477119 
Fax +31 543 475355 

Email : 

[email protected]

 

www.dorset.nu

  

 

Содержание Trovan Access Guard

Страница 1: ...Installation manual trovan Access Guard DATE 5 November 2008 Copyrights DORSET IDENTIFICATION B V The Netherlands Tel 31 543 477119 Fax 31 543 475355 Email id dorset nu www dorset nu ...

Страница 2: ... 5 3 1 LID665A DECODER AND LID665 BACKPLANE 5 3 1 1 LID665A V2 X decoder and LID665A V3 X decoder 5 3 1 2 Description of connector connections LID665BPv14 LID665BPv20 Backplane 6 3 1 3 Schematic overview of LID665BPv14 LID665BPv20 relay outputs 7 3 1 4 How to connect 8 3 2 LID650A DECODER 9 3 2 1 Description of connector connections LID650v3 0 9 3 2 2 How to connect 10 4 POWERSUPPLY LID650 LID665 ...

Страница 3: ...s to the type of transponder The reading distance of each transponder depends on its size and shape Reading distances up to 120cm 47 inch can be achieved when the right combination between transponder and reader is used 2 2 Readers The basic components of the entire system are the access control readers Every reader consists of an antenna and a decoder 2 2 1 Antenna When a transponder is held with...

Страница 4: ... RS232 communication can only be used if a decoder is situated close to the PC up to 14 meters 46ft Figure 1 RS232 communication 2 3 2 RS485 communication The 2 wire RS485 network connection is used when larger numbers of decoders are used or when the distance between decoder and PC is too far for a direct RS232 connection A RS485 network connection requires a RS485 comport card in the PC which is...

Страница 5: ...ed on the LID665BP backplane which contains the physical connections 3 1 1 LID665A V2 X decoder and LID665A V3 X decoder LID665 V2 X LID665 V3 X Note 1 JP1 Solder jumper must be closed when the decoder is at the RS485 bus end See chapter 3 2 for more information regarding RS485 Jumper JP1 should also be set when using RS232 communication 2 If you want to use the hardware trigger input R12 should b...

Страница 6: ...connection 1 Antenna signal 2 Antenna Gnd J18 External LED 1 LED red antenna LED 2 LED red antenna LED J9 Relay output 2 Optional 1 Voltage 5VDC Vin LOW max 50mA or wide range Vin HIGH max 400mA jumper J11 selectable 2 NO Normally Open 3 NC Normally Closed 4 GND J8 Input Output direct from uP 1 TTL signal Output 2 parallel to relay output 2 Green antenna LED 2 TTL signal for input 2 3 Gnd J6 Input...

Страница 7: ...n three different ways No jumper External voltage can be applied to pin 1 of J20 J9 Max 125VAC max 1 Amp Jumper on 1 2 Vin LOW 5Vdc 5 is selected Max 50mA Jumper on 2 3 Vin High 7 24Vdc is selected Max 400mA with EID part number PWS12V 1A 12V 1000mA Important note If you connect an inductive load like an electric lock or relay there should be a free running diode like 1N400x type mounted at the in...

Страница 8: ...J2 7 6 When this decoder is the first or last on the bus then jumper JP1 should be set on the LID665 This jumper sets the termination resistor of 120 Ohm which is on the circuit board 7 When this decoder is the first on the bus 2 resistors should be placed to get a predefined voltage on the bus Place 680 Ohm between J2 3 and J1 2 5V Place 680 Ohm between J2 4 and J2 5 GND Connecting the doorlock 1...

Страница 9: ... contact 4 Gnd J16 Potential free relay output Doorlock 1 Potential Free input or VCC if JP4 closed 2 NC normally closed contact 3 NO normally open contact 4 Gnd J14 Power supply VCC 1 12VDC linear regulated 1 Amp Do not use a switched power supply 2 Gnd J11 Communication port 1 Txd transmit signal RS232 serial port 2 Rxd receive signal RS232 serial port 3 RS485 B 4 RS485 A 5 Gnd Ground interface ...

Страница 10: ... the LID650 This jumper sets the termination resistor of 120 Ohm which is on the circuit board 5 When this decoder is the first on the bus 2 resistors should be placed to get a predefined voltage on the bus Place 1 5 KOhm between J11 3 and J14 1 12V Place 1 5 KOhm between J11 4 and J11 5 GND Connecting the doorlock 1 Set jumper JP4 to use the on board power to switch the doorlock If external power...

Страница 11: ...an be used for 220Vac or 110Vac When using 220Vac R1 has to be placed and fuse F1 is T125mA slow type When using 110Vac R2 and R3 have to be placed and fuse F1 is T250mA slow type J1 220Vac 110Vac Power input J3 Output 12V 1 12V 2 Gnd F1 Input fuse slow type T125mA fuse for 220Vac T250mA fuse for 110Vac F2 Output fuse fast type F1 Amp fuse ...

Страница 12: ...municate via a direct 3 wire RS232 connection NOTES Use a 4 wire double twisted pair cable Put the Txd and Rxd in 2 separate twisted pairs where the other wire of each twisted pairs will be Gnd This results in 1 twisted pair with Txd and Gnd and 1 twisted pair of Rxd and Gnd Don t exceed cable lengths of 14 meters 46ft Use repeaters when distances are bigger The table below shows the RS232 connect...

Страница 13: ...D650 decoders resistor 1 between J6 3 and J8 1 resistor 2 between J6 4 and J6 5 The PC should not be placed at the end of the bus When the PC is detached from the RS485 network the termination resistor on the RS485 PC card will be disconnected and the network will not work The bus length may not exceed 1200 meters 4000ft Do not use branches from the bus to a decoder but make the connection on the ...

Страница 14: ...cations without prior notice 14 6 PC software trovan access guard is delivered with free Windows 95 98 ME 2000 NT XP based PC software The software uses a Firebird database server which is installed on a server PC See the manual of the software for more information ...

Страница 15: ... backplane to an alarm system Connector numbers are described on page 6 Place one decoder into the housing of the alarmsystem and connect the antenna and RS485 communication bus This is the actual alarmunit Connect the potential free relay output J20 1 and J20 2 to the alarmsystems input This potential free contact switches the alarmsystem on and off Connect a wire to J14 2 GND and lead it towards...

Отзывы: