7.2
Cleaning
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Protective equipment:
Use ear protection
Eye protection
Respiratory protection device
Protective workwear
Protective gloves
Anti-Static Safety Boots
1. Purge spray gun
2. Remove material residues with a cloth or
a soft brush.
3. Clean the spray gun carefully and dry it
with a soft cloth.
Clean air cap and nozzle
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Protective gloves
Anti-Static Safety Boots
For a thorough cleaning, air cap and nozzle
must be disassembled.
Disassembly
Fig. 23: Ground electrode
1. Discharge electrode (1) using a
grounding rod (2). In this, pull the trigger
completely.
Fig. 24: Replace air cap
2. Loosen cap nut (3).
3. Remove air cap (4).
4. Pull trigger.
ð
The needle is pulled backwards so
that it will not be damaged during dis-
assembly of the nozzle (5).
5. Unscrew and remove the nozzle (5) with
the supplied open-end wrench (included
in the tool kit).
Cleaning
11/2019
EcoGun AS MAN EC - MSG00022EN
19/52