Rinsing intervals depend on the
material used.
Personnel:
Operator
+ additional qualification high tension
technology
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Respiratory protection device
Eye protection
Use ear protection
Protective gloves
Anti-Static Safety Boots
Requirements:
Technical ventilation is in operation.
Material pressure is switched off.
A collecting tray for material and deter-
gent is available.
1. Switch off electrostatic controller.
2. Set air pressure at the compressed air
controller to 0bar.
3. Disconnect spray gun from the material
supply.
4. Pull trigger.
ð
The residual paint is blown out of the
spray gun.
Collect residual paint in the collecting
tray.
5. Connect detergent supply.
6. Rinse the spray gun with an appropriate
detergent until the detergent runs clean
without any material residue.
ð
Collect detergent in the collecting tray.
7. Ensure proper disposal of the exiting
material and rinsing agent.
8. Depressurize detergent supply.
9. Disconnect detergent supply.
7
Cleaning
7.1
Safety recommendations
DANGER!
High voltage
High voltage can be present on compo-
nents and cables. There is a risk of death
due to electric shocks and discharges.
Before carrying out any work:
– Switch off electrostatic controller.
– Discharge electrode by means of a
grounding rod. In this, pull the trigger
completely.
– Verify no current is present.
WARNING!
Danger of fire and explosion
Flammable coating materials and their
detergents and cleaning agents can cause
a fire or an explosion.
– Ensure that the flashpoint of the fluid is
at least 15 K above the ambient tem-
perature.
– Note explosion group of the fluid.
– Follow safety data sheets.
– Ensure that forced ventilation and fire
protection equipment are in operation.
– Do not use sources of ignition and
open light.
– Do not smoke.
Cleaning
11/2019
EcoGun AS MAN EC - MSG00022EN
17/52