Installation
Potentiometers
Jumpers
NOTE:
Refer to Dart Controls Instruction Manual for 700B Control Series for further details.
Change Acceleration / Deceleration
Settings
1. Remove belt. (See “Belt Removal for Conveyor Without
Stands” on page 13 or “Belt Removal for Conveyor
With Stands” on page 13.)
2. Remove control board mounting screws
22, item 1)
from bottom of plate.
Figure 22
Figure 22
3. Locate potentiometers to change. See Controller Board
layout on page 10.
4. Rotate potentiometers
to desired
setting.
Figure 23
Figure 23
5. Reinstall by reversing steps.
Item Number
Description
Setting
1
Current Limit %
100%
2
Gain %
N/A
3
Max. Speed %
100%
4
Min. Speed %
5%
5
Decel. (0-10 sec.)
0 sec.
6
Accel. (0-10 sec.)
0.5 sec.
Item Number
Description
Position
Setting
7
Input Voltage (P3)
P3-2 & 3 (36)
24/36 VDC
8
Sensor Spacing (P2)
P2-1 & 2 (120)
120 deg.
9
Potentiometer Function (P5)
P5-2 & 3 (U)
Unidirectional
A
WARNING
Exposed moving parts can cause severe
injury. LOCK OUT POWER before removing
guards or performing maintenance.
1