Dorner Mfg. Corp.
26
851-946 Rev. A
AquaPruf® Positive Drive Conveyors
Preventive Maintenance and Adjustment
Belt Return Maintenance
Belt Returns 660 mm Wide and Wider
1. Remove belt return assembly
from
slotted holes
on each side of
conveyor frame.
Figure 74
Figure 74
2. Insert an 8 mm
and 6 mm
hex wrench into the retainer plate.
Figure 75
Figure 75
3. Move wrenches toward each other to unlock the retainer
plate
and remove from the shaft.
4. Remove puck
from the shaft.
Figure 76
Figure 76
5. Repeat steps 3 through 5 as needed.
6. Install new pucks with retainer plates on both sides.
a.
Insert an 8 mm
and 6 mm
hex wrench into the retainer
plate.
Figure 77
Figure 77
b. Move wrenches toward each other to open the
retainer plate
and install onto
the shaft. Position retainer plate where needed.
c.
in
place, move the wrenches
away
from each other.
Figure 78
Figure 78
WARNING
SEVERE HAZARD!
LOCK OUT POWER before removing guards
or performing maintenance. Exposed moving
parts can cause serious injury.
1
2
1
2
3
1
1
2
3
2
1
2