5.
Tighten the clamping screws of the side panel.
Tightening is 15 Nm.
6.
Remove all assembly blocks.
Fig. 63
5.
6.
Mounting the glass door leaf
4.5 Prevent excessive opening of
the door
The double action door may be opened max. 90°.
Prevent excessive opening of the door, e.g. by using a
doorstop.
Fig. 64 Doorstop to prevent excessive opening
5 Adjusting the “0”
position
The “0” position is the prerequisite for the self-closing
function. The “0” position is the door leaf position
with the door closed. Double action hinges are
delivered with the “0” position not adjusted.
1.
Remove all assembly blocks or the like.
2.
Bring the glass door leaf in the ideal “0” position
(Fig. 65).
Fig. 65 Ideal “0” position from the glass door leaf to the side
panel
3.
Tighten all screws (2 x upper hinge and
2 x lower hinge). Tightening is 5 Nm (Fig. 66)!
Fig. 66 Position of the screws
4.
Finally, check the swing action of the door.
If the glass door leaf does not close in the ideal
“0” position, loosen the screws again and readjust
the “0” position.
5.
Press in the cover caps.
Fig. 67
Mounting the cover caps
22
TENSOR
2017-11
WN 059361 45532
dormakaba Mounting instructions
Adjusting the “0” position