4.2.3 Fix mounting plates
1.
Attach the mounting plate with 4 countersunk
screws (M6 x 12) to the TENSOR double action
hinge (Fig. 49).
2.
Check that the screws are tight. Tightening is
12 Nm.
Fig. 49 Attaching the mounting plates to the double action
hinge
4.2.4 Clean glass surfaces
Clean glass surfaces around the clamping areas. Use
commercial glass cleaner. Do not use thinners!
4.2.5 Attach the double action
hinge onto the glass door
leaf
1.
Set the glass door onto assembling trestle.
2.
Place the prepared TENSOR double action hinges
into glass cutout and align.
3.
Mount counter plates. Tightening is 15 Nm.
Fig. 50 Mounting the double action hinge onto the glass door
leaf
4.2.6 Mount the glass door leaf
onto the wall
ATTENTION
Risk of damage to the glass door leaf by
contact with hard materials (e.g. glass,
metal, concrete)
The contact may cause conchoidal fractures,
damage the edges and/or break the glass
off the glass door.
Damaged glass door leaves should not be
installed – risk of injury. Protect glass edges
with spacers!
1.
Place the glass door leaf at the mounting position
on wooden blocks or similar objects and align
vertically. Observe the gaps (see Fig. 39 on p.
15)
Fig. 51
Vertical and perpendicular mounting position of the
double action hinge
2.
Mark the drilling pattern of the upper and lower
double action hinge.
Fig. 52
Drilling pattern of the double action hinge
3.
Remove glass door leafs and place them on
wooden blocks or similar objects.
4.
Drill the holes. Diameter corresponding to the
technical notes of the selected mounting material.
5.
Place the glass door leaf in the correct position.
6.
Plumb the mounting plates if they do not abut
against the wall in the vertical position of the
glass door leaf.
18
TENSOR
2017-11
WN 059361 45532
dormakaba Mounting instructions
Mounting