Non-Display Keypad Setup
Follow these steps to configure the Input Signal on a Non-Display Keypad:
1.
Using the Keypad, input the following keystrokes:
#16 + (Master ID and Combination) + (Input Signal Mode)* + (Enter key)
*(0 = Ignore, 1 = Remote Disabled, 2 = Remote Time Delay Override, 3 = Remote Dual User Override)
As an example, if your Master ID was 00 with a Combination of 12345678, you
would enter #1600123456781 to set up the Input signal for Remote Disabled.
2.
The Keypad will beep three times and flash a green LED once complete.
Alarm Box & Input Signal Overview
The Alarm Box (Item/Order # 704045) allows for a Remote Disable input signal that
can block the open command to the lock if asserted. The Alarm Box is not UL evaluated.
(Item/Order # 704045, “Alarm Box”)
Connecting the Input Signal
This section outlines how to connect the Input Signal from your alarm/control system to
your 700 series Lock and Keypad using the Alarm Box to make use of the Remote
Disable function.
Mount the Alarm Box
Mount the Alarm Box to the interior safe wall via the holes and screws provided.
Connect the Alarm Box
For multi-lock configurations, the silent alarm works only with the primary lock (the lock
connected to Position 1 on the Multiplexer). This guide outlines connections to primary
locks only.
Follow these steps to connect an Alarm Box to a LA GARD safe lock:
1.
Disconnect the safe lock from the power supply.
2.
Connect the Alarm Box lock connector to the safe lock BAT port with the
41040-2 cable.
3.
Connect the alarm/control system to the Alarm Box via the terminal block.
Based on the terminals used, the alarm relay can be configured to Normally
Open (COM and NO) or Normally Closed (COM and NC).
4.
Optional: Connect the Remote Disable signal from the alarm/control system
to EXT+ and EXT- via the terminal block.