background image

4 / 12

DOOR PREPARATION CHART

SEE TRIM INSTALLATION INSTRUCTIONS, TEMPLATES, OR 

DOOR PREPARATION DOCUMENTS FOR DETAILS.

CL

CL

X

X

METAL

ROD GUIDES

#25 DRILL

#10-24 TAP

TOP STRIKE

#25 DRILL

#10-24 TAP

METAL

METAL

LATCHES

METAL

#25 DRILL

#10-24 TAP

SURFACE MOUNT

WOOD

¹/

8

" DRILL

PILOT 1" DEEP

DRILL THRU

1/4" DRILL

(DEVICE SIDE)

DRILL

(TRIM SIDE)

METAL

WOOD

SEX BOLTS

INSIDE

OUTSIDE

RHR

LHR

RHR shown(LHR opposite)

¹/

4

" Radius

CUT-OUT

DEVICE SIDE ONLY

/

8

" DEEP FOR

WOOD DOOR

#7 DRILL

#1/4"-20 TAP

#25 DRILL

#10-24 TAP

METAL

SURFACE MOUNT

N/A

¹³/

32

"

¹³/

32

"

USE SUPPLIED MOUNTING 

HARDWARE OR APPROPRIATE 

FLOOR ANCHORS FOR THE 

APPROPRIATE BOTTOM STRIKE

END CAP BRACKET 2-HOLES

CENTER CASE 2-HOLES

CENTER CASE 2-HOLES

BOTTOM STRIKE

DOOR CUT-OUTS

USE APPROPRIATE 

TEMPLATE FOR THE 

SUPPLIED STRIKE

PREPARE HOLES FOR THE END CAP BRACKET 

MOUNTING HOLES AFTER THE EXIT DEVICE 

CENTER CASE INSTALLATION AND AFTER 

LEVELING THE EXIT DEVICE.

Level

5/16” DRILL

ON DEVICE SIDE

13/32” DRILL

ON TRIM SIDE

13/32” DRILL

THRU

1/8” DRILL

PILOT HOLE 1” DEEP

1/8” DRILL

PILOT HOLE 1” DEEP

WOOD

WOOD

WOOD

WOOD

5/16" DRILL ON DEVICE SIDE

13/32" DRILL ON EXTERIOR SIDE 

(FOR THRU BOLTS)

1/2" DRILL THRU HOLE 

(FOR TRIM POSTS)

1/8” DRILL

PILOT HOLE , 1” DEEP

 

13/32" DRILL THRU  

(FOR THRU BOLTS)

1/2" DRILL THRU HOLE 

(FOR TRIM POSTS) 

Fire Exit Hardware 

is to be installed on 

Fire Doors bearing 

the marking “Fire 

Door to be equipped 

with Fire Exit 

Hardware” Any 

retrofit or other field 

modification to a Fire 

Rated opening can 

potentially impact the 

Fire Rating of the 

opening.

  IMPORTANT:

• Use supplied templates for field installations.

• Use door preparation documents for door/frame manufacturing. 

• Door must be properly reinforced where the exit device chassis and latches 

are mounted. The surface must be flush and flat within 1/16" (1.5 mm).

• Prepare the interior of the door using the exit device template or door 

preparation and instructions.  

• Prepare the exterior of door using the trim template or door preparation and 

installation instructions.  

• All threaded holes require a minimum material thickness 

of 0.125" (3 mm). 

• We recommend samples be used to verify preparation before mass door or 

frame manufacturing. 

• NOT RESPONSIBLE for any physical or property damage due to incorrect / 

improper preparation or installation.

FOR DOOR PREPARATION 

REFERENCE ONLY. 

Verify that this is the latest version of 

this document. We recommend 

samples be used to verify preparation 

before door / frame manufacturing. 

SURFACE 

MOUNT

FOR THRU BOLTS

OR TRIM

METAL

METAL

WOOD

Содержание DX2 FV

Страница 1: ...nstructions templates and door preparation BEFORE starting any installation or door preparation 2 Prepare door for the installation of the exit device and any applicable trim 3 Follow exit device and...

Страница 2: ...Sleeve Side Screws Rod Guide Screws Bottom Strike Latch Cover Screws Latch Screws Strike Screws Sex Bolts End Cap Bracket Screws End Cap End Cap Screws End Cap Bracket Cover Plate Mechanism Case Spad...

Страница 3: ...6 7 PCS No 10 12 x 1 11 32 7 PCS L No 1 4 20 x 5 8 1 PCS No 1 4 20 x 5 8 1 PCS E N O B E Trim mount or sex bolts F No 10 24 x 11 16 2 PCS Center Case Screws No 10 12 x 1 11 32 2 PCS E A No 10 24 x 1 1...

Страница 4: ...THRU HOLE FOR TRIM POSTS 1 8 DRILL PILOT HOLE 1 DEEP 13 32 DRILL THRU FOR THRU BOLTS 1 2 DRILL THRU HOLE FOR TRIM POSTS Fire Exit Hardware is to be installed on Fire Doors bearing the marking Fire Doo...

Страница 5: ...ed minimum stile is 2 1 8 with additional 1 2 glass stop Aluminum doors with a 2 1 8 stile width cannot have a door stop on the door lock side edge 1 CAUTION Prior to using supplied templates verify t...

Страница 6: ...ed without a trim If a 5 8 diameter hole is required for the electrified exit device the hole must be positioned as shown E F 1 3 16 Center Case Screws Optional Trim 7 16 1 Following the marking of th...

Страница 7: ...s 3 Insert cover plate then slide anti rattle clip into position minimum 2 from end before fixing end cap with supplied screws 1 Align top latch with top strike then install top latch with two mountin...

Страница 8: ...t cannot be retracted when the door is closed and the deadlock depressed If not adjust the strike position to engage with the device deadlock DXAS215 DXAS106 DXAS108 Once the latchbolt is adjusted pro...

Страница 9: ...bar and ensure that the bottom latch is retracted and stays retracted after the door is opened Adjust the retractor screw if needed 2 Close the door and ensure that the bottom latch engages in the bo...

Страница 10: ...for the Fire Bolt Position Fire Bolt 4 to 6 above the finished floor 2 Drill 1 hole in the door edge as indicated and drill and tap for 8 32 machine screws 3 Install Fire Bolt on edge of door and fas...

Страница 11: ...f cylinder is not installed remove cover plate and install cylinder with cam orientation as shown below Depress push bar and turn flat hex key or cylinder key one full turn for dogging check For Alarm...

Страница 12: ...WD OD002 682 DX2PV FV INST 2021 11 12 12...

Отзывы: