DOOR
EDGE
STOP
FACE
RIGHT HAND REVERSE APPLICATION
8”
203 mm
4
1/2”
114 mm =180°
2
1/4”
57 mm
1”
25 mm
1”
25 mm
5”
127 mm
2
3/16”
56 mm
DOOR
EDGE
STOP
FACE
2
1/4”
57 mm
5”
127 mm
2
3/16”
56 mm
1”
25 mm
LEFT HAND REVERSE APPLICATION
1”
25 mm
9
3/4”
248 mm =110°
6
1/4”
159 mm =180°
DOOR
STOP
1
11/16”
43mm
1
1/16”
27mm
1
3/4”
44mm
5/16”
8mm
11/16
17mm
RIGHT HAND REVERSE SHOWN,
LEFT HAND REVERSE OPPOSITE
8”
203 mm =110°
4
1/2”
114 mm =180°
Power
Adjustment
DOOR WIDTH
INTERIOR EXTERIOR
SET TO
I
II
III
IV
V
VI
8.5 lb-f
32
(813)
36
(914)
42
(1067)
48
(1219)
36
(914)
38
(965)
42
(1067)
48
(1219)
54
(1372)
-6
-3
+0
+6
+10
+14
FULL TURNS
OF SPRING
ADJUSTING NUT
- Latching speed.
- Swinging speed.
- Delay Action for regular arm. 120°opening.
- Delay speed with parallel arm. 90° & 180°opening.
1
2
3
4
5
6
NO.1
NO.2
DA
BC
Power
Adjustment
- Back Check for regular arm. 120°opening.
- Back Check with parallel arm. 90° & 180°opening.
1
3
2
4
ARM441HDE - EXTRA DUTY PARALLEL ARM
PUSH SIDE MOUNTING (110°- 180°)
INSTALLATION INSTRUCTIONS
ARM441HDE-INST 2019-01 1/2
=110°
SOFFIT
SOFFIT
Using a wrench rotate the door closer bottom shaft, about
30° towards the hinges, insert main arm on top shaft and
secure arm on shaft with supplied screw
1/2”
13 mm
Door closer and arm must be parallel during the door
opening range. Misalignment will cause strain and
bending on the arm and door closer and will affect the
door closer smooth operation. Position door closer at
the appropriate position, verify its levelness and
secure on door using the appropriate supplied screws.
Orientate arm plate and position under the frame stop face soffit
surface at the specified orientation and distances and secure plate on
frame stop face soffit using the appropriate supplied screws (5x).
Before drilling mounting holes on the frame, ensure
that the arm is properly oriented, as instructed
in step 2.
Use extra mounting screw for additional
support. Use spacer (if required)
REFER TO INSTALLATION INSTRUCTIONS AND DOOR CLOSER ADJUSTMENT
INSTRUCTIONS SUPPLIED WITH DOOR CLOSER
IMPORTANT INSTALLATION NOTES
AFTER INSTALLATION, PLEASE VERIFY:
1. Open the door do its maximum opening angle and release:
a. The door should close fully into the door frame and latched into the strike
2. Hold the door open and rest the latch bolt on the strike plate, then release the door:
a. The door closer should have sufficient power to latch the door.
3. Back-check provides a cushioning effect when the door is forcibly thrown open but does not serve as substitute for a door stop.
MAINTENANCE
1. Check the door closer every three months to ensure all fixings are secure and adjust, if necessary, adjust the closing and latching
speeds and verify the door functions properly and smoothly in accordance to ANSI A156.4 G1 norms.
2. Apply light oil to door closer arm joints and door hinges.
WARNINGS
1. Spring power settings of 1 or 2 are NOT SUITABLE for use on fire/smoke door assemblies.
2. The mechanical hold open devices MUST NOT BE INSTALLED on fire/smoke door assemblies.
3. The door closer should NOT BE OPENED beyond its maximum opening angle of the power size selected.
4. This door closer contains a powerful spring which is installed into the body at high pressure.
Under no circumstances should anyone attempt to dismantle the door closer
Rotate arm on door closer until the elbow is
about 1/2” (13 mm) from the door surface.
SPACER
(IF REQUIRED)
NOTE:
Parallel arm installation reduces the door closer maximum power size to V (5) for
110° door opening and to size IV (4) for 180° door opening angles.
in (mm)
FOLLOW STEPS 1, 2, 3, 4