3.2. Starting
3.2.1. Operation 1 (Analog panel)
After checking the warning lamps of the gauge panel and the NEUTRAL position of reduction gear control
lever, turn the key switch to the START position to crank the engine, at once.
Behavior - When the key switch is placed in the START position.
After the engine is cranked, convert the key switch to the ACC position quickly.
Behavior - As the engine is cranked, don’t fix the key switch too long (over 4 seconds) in the
″
START
″
posi-
tion. If you do, the starter may be malfunction.
If you fail the engine starting at first, restart the engine after waiting for 30 seconds at least to pre-
vent the circuit malfunction of the starter.
3.2.2. Operation 2 (Digital panel)
Digital panel system boot, shutdown and the engine stop function.
1) Insert the key into key switch on the product, please rotate 90 to the right (ON) (When the key is turned
″
ON
″
, keeping the key jammed)
2) After key on, all the system boot in 17 secs.
3) When turn off the system rotate the key 90 to the left (OFF)
●
When you rotate the key from the ignition state to the left (OFF) the 300 seconds alarm message pop-
up on the window then engine shutdown after 300 seconds with saving event.
●
When a pop-up appears, if you rotate the key to the right (ON) pop-up disappears then the engine will
remain on.
Refer to
″
User's Manual for Digital Panel
″
for details.
Содержание AD158TI
Страница 2: ......
Страница 16: ...Specification 10...
Страница 25: ...Commissioning and operation 19 2 Digital gauge panel Circuit diagram EDV2218035...
Страница 34: ...Commissioning and operation 28...
Страница 56: ...General information 50...
Страница 70: ...Main accessory parts 64...
Страница 120: ...Disassembly and assembly of major components 114...
Страница 172: ...Main parts maintenance 166...
Страница 187: ...Governor Actuator Controller...
Страница 188: ......
Страница 221: ...33 6 Product dimension 170 130 140 153 165 6 19 4 6 EDL11160004...
Страница 253: ...HY DP MANUAL 001 Digital Panel for Marine Engines Service Manual Ver 1 0 Doosan Infracore...
Страница 294: ......