7.5.2 Robot Limits Setting
It sets the safety limits of safety monitoring functions.
Note
The limit and initial safety settings may vary according to the robot lineup.
Safety limits is the condition where the safety-rated monitoring function triggers the stop
function. When stop is completed, the position of the robot and force applied externally may
differ from the configured safety threshold.
TCP/Robot Limits
To set the TCP/Robot Limits, go to the
Robot
Workcell and select
Robot
>
Robot Limits >
TCP/Robot
. The TCP/Robot Limits setting screen layout is composed as follows:
No.
Item
Description
1
Force (N)
It can limit the force level applied to the tool center point (TCP).
2
Power (W)
It can limit the mechanical power level of the robot.
3
Speed (mm/s)
It can limit the speed of the tool center point (TCP).
4
Momentum
(kg.m/s)
It can limit the momentum size of the robot.
1
5
2
3
4
6
Содержание A0509
Страница 1: ......
Страница 76: ...Doosan Robotics User Manual v2 6 1 76 Tapping the Edit button cannot edit the setting but deletion is possible ...
Страница 117: ...117 Note The configuring end effector and base end effector must be symmetrical on the tool Z axis ...
Страница 121: ...121 7 8 2 Vision For more information about Vision settings refer to the separate Reference Manual provided ...
Страница 214: ...Doosan Robotics User Manual v2 6 1 214 ...
Страница 251: ...251 ...
Страница 252: ...Doosan Robotics User Manual v2 6 1 252 ...
Страница 253: ...253 ...