![Doosan A0509 Скачать руководство пользователя страница 234](http://html.mh-extra.com/html/doosan/a0509/a0509_user-manual_2521486234.webp)
Doosan Robotics User Manual v2.6.1
234
Warning
•
Friction calibration must be performed with a temperature of at least 40
℃
(313 K) or higher
throughout warm-up for each axis of the robot. Doosan Robotics does not assume responsibility
for any robot motion problems or various other issues caused by failing to comply with this
condition.
12.14 KT Smart Factory Setting Screen
This screen sets the KT Smart Factory function.
1
Tap the
Settings
button and select
KT Smart Factory
.
2
Enter values according to the validation of each item.
3
Items required are IP address, port value, Device ID, Device Password, Gateway ID and
transmission frequency.
4
Pressing the
Confirm
button applies the entered values.