9510-065-D-3-10 - Draft - Not for Release
29
4.3 Manual Gate Operation
Caution:
Never attempt to manually operate any gate until you have verified that power to the operator has been shut-off.
Gate Frame
Interlock
- Cuts off AC
power to the operator.
Padlock
Bracket
Chassis
Cover
Catch
Inside
Cover
Catch
Padlock
Bracket
Manual Crank Stored
1.
Lift cover on padlock bracket end a few inches.
2.
Slide cover horizontal to free cover from chassis cover catch.
3.
Lift cover off vertical.
BE CAREFUL not to hit internal components with cover!
Idler Wheels
Padlock
Not Provided
1
2
3
Manually
Crank
Remove the Cover
1
2
Insert the supplied manual hand crank into the motor
shaft underneath the interlock door. Turn the crank to
open the gate. Speed brake model operators
MUST
also have the speed brake manually released before
manually cranking the hand crank.
Speed Brake Release on Select Models
The speed brake
MUST
be manually released (disengaged) with the
release handle 90° before manually operating the gate.
Speed brake will automatically reengage
after power has been restored.
Release
Speed Brake