9510-065-D-3-10 - Draft - Not for Release
15
NC
NO
7
20
19
19 18
18
17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
Current Sensor
Current Sensor
Circuit Board Earth Ground
120 V Hot Input to Circuit Board
120 V Neutral Input to Circuit Board
Dr
y Relay Contact
Gate T
racker - Data
Gate T
racker - Busy
Alarm Output
Alarm Reset Input
Full Open/Close - Exit Loop Logic Output
(DoorKing Loop Detectors ONL
Y
)
Dr
y Relay Contact
24 V
AC Radio Receiver Power Only
(250 ma. maximum)
Full Open and Close Input
Partial Open Input
Reverse/Stop Input
Low V
o
ltage Common
Low V
o
ltage Common
Low V
o
ltage Common
Radio Receiver Low V
o
ltage Common
3-Button Full Open Input
(DoorKing 3-Button Control Station ONL
Y
)
3-Button Full Close Input
(DoorKing 3-Button Control Station ONL
Y
)
4404
•
When gate is closed, this input will open gate
to full position.
•
When gate is open and auto
close timer SW 1, switch 2 is
turned ON, input will re-set and hold timer.
•
When gate is open and auto close timer SW 1,
switch 2 is turned OFF, input will close gate.
•
When gate is closing, input will reverse gate.
For long gate applications. This input will
open the gate to the middle limit nut setting,
See page 24 for limit nut descriptions.
2
Operation of relay is dependent on setting
of SW 1, switches 4 and 5. See page 22
for DIP-switch function descriptions.
Relay contacts can be set for Normally
Open (NO) or Normally Closed (NC)
operation.
Contact rating is 1 amp maximum at
24-volts DC.
1
ON
23
45
67
8
NC
NO
SW 1 is Upside-Down on Board
1
ON
SW 1 is Upside-Down on Board
2
34
56
78
SW 1 is Upside-Down on Board
1
ON
2
34
56
78
SW 1 is Upside-Down on Board
1
ON
23
45
6
7
8
•
When gate is fully closed or in the opening cycle, this
input has no effect on the gate.
•
When gate is open:
auto close timer
SW 1, switch 2 is turned
ON
, input will
re-set and hold timer.
•
When gate is open:
auto close timer
SW 1, switch 2 is
turned
OFF
, input will prevent gate from closing.
•
When gate is closing: input will
reverse
gate when
SW 1, switch 7 is
OFF
.
•
When gate is closing: input will
stop
gate when SW 1, switch 7 is
ON
. Gate
will continue to close after input is cleared.
5
6
DoorKing’s Remote alarm reset
station can be connected. See
page 18 for wiring.
It MUST be mounted in the
line-of-sight of the gate operator.
(DoorKing P/N 1404-080)
Used in conjunction with
the circuit board reversing
sensors. See page 25 for
further information.
15 14
12 11
16
17
DANGER
HIGH VOLTAGE!
2.3 Main Terminal Description
Auxiliary Common
Terminal
Содержание Series 9500
Страница 2: ......