background image

120 S. Glasgow Avenue

Inglewood, California 90301

U.S.A.

Stand-Alone Power and Device Wiring :

 Connect 12 - 24 Volt AC or DC power to 

terminals #1 and #2. Use minimum 18 AWG wire to power the receiver.

•  If DC power is used (Transformer): Terminal #1 is 

NEGATIVE

 and Terminal #2 is 

POSITIVE

.

•  Connect the receiver relay contacts to the device to be activated.
  - Receiver Terminal #3 is the relay contact 

Normally OPEN

 (N.O.)

  - Receiver Terminal #4 is the relay contact Normally CLOSED (N.C.)
  - Receiver Terminal #5 is the relay contact 

Common

 (C).

MODEL 8057 MicroCLIK

 RF RECEIVER

Installation

Receiver Terminal Wiring

DoorKing Part Numbers

The model 8057 

RF Receiver

 is designed for use with Micro

CLIK

™ transmitters. The receiver can store 10 facility codes and 50 to 

16,000 unique transmitter codes depending on the model selected. It is also programmed to recognize only certain transmitter 
buttons.
The 8057 has a built in programming keypad allowing transmitter codes to be block coded or individually added/deleted to its 
memory. It is a stand alone receiver that activates a built-in dry contact form “C” relay when a programmed transmitter code is 
received. The received code 

MUST 

match the programmed 

“Facility Code”, “Transmitter Code”, 

and

 “Transmitter Button Code”

  

before the receiver relay will activate.
The Micro

CLIK

™ system is compatible with

the HomeLink system found in many
automobiles.

This receiver is 

NOT

 designed to be installed outdoors without being protected from the weather. An outdoor enclosure is available for the receiver 

if required (P/N 8057-110 - Metal Outdoor Box).
Install the 8057 receiver in a location so the antenna is 

NOT surrounded by metal and is in free air as high as possible above the ground.

A longer Coax Antenna kit is available for the receiver if required (P/N 1514-073 - Includes antenna, mounting “L” bracket and 15 feet of coax 
cable).
The RF LED on the side of the case will blink as RF energy is received. If the LED blinks or is on continuously, this indicates that there may be 
interference on the frequency (318 MHz) and short range may be the result. If this happens, try relocating the receiver or remove the source of 
interference.

Note:

 Loop detectors and proximity card readers can cause receiver interference.

To Receiver Terminal #1 (Neg.)
To Receiver Terminal #2 (Pos.)

12-24 Volt
Transformer

P/N 8066-080

P/N 8067-080

P/N 8068-080

From “Low Voltage Common”

From “Radio Open”

From “Circuit Board” Power

1 Button

2 Button

3 Button

Micro

CLIK

™ Transmitters

Gate Operator:

 

 Connect the 

3 wires from the gate operator 
as indicated.

To Receiver Terminal #1

To Receiver Terminal #2

To Receiver Terminal #3

DC Polarity Matters!

Removable receiver  
terminal for easy wiring.

8057-081

50 Transmitter Codes

8057-082

100 Transmitter Codes

8057-083

250 Transmitter Codes

8057-084

500 Transmitter Codes

8057-085

1000 Transmitter Codes

8057-086

5000 Transmitter Codes

8057-088

16,000 Transmitter Codes

F Connector

Coax Antenna Kit

(Included)

18” Coax Cable

3

2

1

6

5

4

9

8

7

#

0

*

8

7

0

*

9

#

2

1

3

5

4

6

Master Cod

e Button

(See next page)

1 2

3 4

5

6 7

8

Receiver
Terminal

RF LED

#1 - Input Power 

12-24 Volt AC, 12-24 Volt DC (Negative)

 

#2 - Input Power 

12-24 Volt AC, 12-24 Volt DC (Positive)

#3 - Relay Contact (Normally Open)
#4 - Relay Contact (Normally Closed)
#5 - Relay Contact (Common)
#6-8 - Not Used

Terminals 3-4-5
rated for 30 volt,
1 amp max.

Отзывы: