3.2 Continued
Switch 1
This switch is a self-test feature that checks various functions of the circuit board and is used for bench test only.
Do not run this test with the operator connected to the gate.
Switch 2
Not Used, leave in the
OFF
position.
Switch 3
Not Used, leave in the
OFF
position.
Switch 4
Spare switch, leave in the
OFF
position.
SW 1
Typical Settings
SW 2
Typical Settings
The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on
or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then
turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator.
Switch Definitions
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
Switch 1
Motor direction switch -
Must
OPEN the gate upon initial AC power up and open command. If the open command
begins to close the gate, turn AC power off and reverse this switch.
Switch 2
Turns the auto-close timer on or off. Can be adjusted from 1 to 23 seconds to close gate.
Switch 3
A device wired to terminal #4 (Switch 3
ON
) is a normal full open input. The output wired to terminal #4 (Switch 3
OFF
) becomes the output of a plug-in loop detector that is installed in the EXIT loop port of the circuit board (Which must be
installed for the
“OFF”
setting to function).
Switches 4-5
These work in conjunction with each other and determine when the relay on the board will be activated. This relay
can be used as a switch for various functions such as illuminating a warning light when the gate is moving, or turning on a
green light when the gate is full open. If a magnetic lock is used with the gate operator, these switches must be set for magnetic
lock operation which limits the relay to activate only when the gate is opening and full open.
Switch 6
Warn Before Operate, When set to the
ON
position, the internal alarm in the operator will start sounding 2-3 seconds
prior to the gate starting and continue throughout the gate’s cycle.
Switch 7
(Switch 7 MUST be
OFF
) Input to terminal #6 will reverse gate. The closing gate that gets activated will reverse back to
the open position.
DO NOT
use ON setting.
a
SHADOW loop
connected to terminal #6 input will only be active when the gate is in the fully opened position, see page 26.
Switch 8
Turning the quick-close feature on will cause the auto close timer to close the gate after 1 second, regardless of the
setting of the auto close timer potentiometer. This will also cause an
opening gate
to stop and reverse when the reverse loops
and/or N.O. photo sensors are cleared. This feature, along with turning switch 7
ON
above, is useful to help prevent tailgating
vehicles from unauthorized entry.