Wiegand Keypad / Card Reader
These instructions apply to the following DoorKing Products: 1815-247, 1815-248, 1815-249, 1815-250 with circuit
board P/N 1515-009.
When used to control entry through an automated vehicular gate system, the keypad / card reader must be
mounted a minimum of 10-feet away from the gate and gate operator, or mounted in such a way that the
person using the keypad cannot come into contact with the gate or gate operator.
Both the keypad and card reader output their data in a 26-bit wiegand format and must be connected to an access
controller such as the DKS models 1833, 1835, 1837 or 1838. Each device operates independently of each other.
Orange
Gray
Re
d
Bl
a
ck
G
reen
Wh
it
e
1 Common (Black)
2 Power (Red)
3 Earth Ground
4 Wiegand Common
5 Not Used
6 Data 0 (Green)
7 Data 1 (White)
8 Not Used
Gray
12-24 Volt AC or DC
Orange
12-24 Volt AC or DC
Green
Data 0
White
Data 1
Black
Common
Red
Power
Power for LED Lights
To Access Controller
Keypad OR Card opens door/gate
Connect the keypad terminals to the card reader terminals (Red,
Black, Green, White) and then connect to access controller.
Keypad AND Card opens door/gate
Each device must have separate weigand wire runs to the
controller with each device operating a different controller relay.
Relay contacts are wired in series to device to be controlled.
Suggest setting relay strike times to 5 sec.
Keypad / Card opens different doors/gates
Each device must have separate weigand wire runs to the
controller with each device operating a different controller relay.
Relay contacts are wired to individual devices to be controlled.