64
742.641 | 11.43
EN
When the self test has finished, proceed as follows:
7. Press
several times until the status message
Self
test
passed
is displayed (Fig. left).
8. Press
SET
to confirm the result of the self test. The sta-
tus display appears.
Status message
Description
Remedy
An
error
was
detected
An internal error prevented the self test
from starting.
Contact your installer if this error
occurs
frequently
.
Not
enough
sunlight
The self test was not started or was can-
celled due to insufficient sunlight, especially
in the evening/at night.
Repeat the self test during the day
when the inverter is feeding the
grid.
Invalid
grid
conditions
The self test was cancelled due to invalid
grid conditions, e.g. due to insufficient AC
voltage.
Repeat the self test later.
MSD
not
ready
The self test was not started because the
inverter was not ready for operation.
Repeat the self test a few minutes
later when the inverter is ready for
operation and is feeding.
Tab. 10: Status messages of errors that prevent the self test from running
Содержание High Efficiency 3.0
Страница 111: ...109 742 641 11 43 Zertifikate Certificates Certificats ...
Страница 112: ...110 742 641 11 43 ...
Страница 113: ...111 742 641 11 43 ...
Страница 114: ...112 742 641 11 43 ...
Страница 115: ...113 742 641 11 43 ...
Страница 116: ......