13
Donaldson Company, Inc.
Filter Removal
1. Turn power to collector OFF.
2. Remove the filter access covers by turning the knob
counterclockwise.
3. Break the seal between the filter cartridge and the
sealing surface.
4. Slowly rotate the cartridge 1/2-turn to remove dust
that may have accumulated on the top of the filter.
5. Slide the filter out the access port along the
suspension yoke and dispose of properly.
6. Inspect and clean the sealing surface if necessary.
Clean dust from gasket sealing
area to ensure a positive filter
gasket seal.
7. Check for an accumulation of dust in the storage
area and empty as necessary.
suspension yoke
filter cartridge
extraction arm
filter access cover
Filter Removal and Replacement (arm may vary from drawing)
Filter Installation
1. Slide the new filter cartridge onto each suspension
yoke.
Insert the filter, gasket end first.
2. Wipe cover gaskets clean and replace covers.
Tighten securely by hand.
Insepct and replace any covers
with damaged or missing
gaskets. Failture to do so may result in leakage
in the collector.
Tighten access covers securely by hand.
Gaskets must be compressed to seal properly.
3. Turn electrical power and compressed air supply ON
before starting unit.