9. Trim the 1-in diameter hose to extend into the
drum at the desired drum-full level.
Note:
Dust with low-bulk density such as weld
fume require the hose to be immersed a
minimum of 6-in.
10. Place the cover on the drum and position under
hopper.
11. Splice into the dirty-air plenum
s air tubing and
insert the nylon barbed tee.
12. Install 3/16-in diameter tubing between the
open branch of the tee and the center barbed
fitting on the gauge assembly. Trim excess
tubing.
gauge assembly
1/4-in thick
washer
coupling
drum full
level
barbed nipple
1-in diameter
hose
Note:
Dust with low-bulk
density such as weld
fume require the hose
to be immersed a
minimum of 6-in.
Drum Sentry Step 9