Extended Dirty-Air Plenum
Air Management Module
Extended Dirty-Air Plenum
The extended dirty air plenum is used in applications
requiring an air management module, an end inlet, or
when a single inlet serves multiple modules.
When positioned an an end module, it is supplied with a
stanadard 2 x 47-in covered opening that may be used as
an access or inlet area.
Specify the location of the opening as top, front or side
of the extended dirty air plenum although front or side
locations limit the area to 36 x 36-in.
Air Management Module
The air management module is used in applications
involving heavy grain loading, large or abrasive particles
in the airstream, or in applications when a collector with
a single inlet serves multiple modules. It is equipped with
a louvered panel near the bottom, which prevents re-
entrainment of the dust that falls through to the hopper.
This module does not contain filters, and is available for
use with an extended dirty-air plenum only.
When the air management module is positioned as an
end module, it is supplied with a standard 24 x 27-in
covered opening.