background image

Page 20

REV.  2014-11

1.  The first 5 years: 

    If, during this 5- 

year period, and in the course of a normal 
use, a component part of the fireplace 
becomes defective due to a material or 
workmanship defect, this part will be 
replaced or, at our discretion, repaired 
free of charge.  The following parts are 
excluded from this warranty:

Any fireplace modified, 

altered or containing substituted  
c o m p o n e n t s   o r   w h e n   t h e  
instructions for installation, 
operation or maintenance have not 
been followed.

1.4  Gaskets:

  Fireplace gaskets are 

8.

  The duration of the warranty on any 

warranted for  90 days  following the  part  that  is  the  object  of  a  claim  must
date of purchase.  

never exceed the total duration of the 
original warranty of the part shipped with 

2.  20-Year Replacement Plan:

  After  the fireplace.

the expiration of the first 5 years, and for 
an additional 20 years period following 

9. Draft and smoke returns:  

All Don-

the date of purchase, we will ship (at the  Bar fireplaces are designed and tested to 
exception of transport  expenses and  operate with a positive draft, without 

1.1  Hearth back plate, smoke 

parts described in the articles 1.1, 1.2,  smoke returns, when installed according 

deflector, HE deflector system, 

1.3  and 1.4) any defective part for a price 

to  the  manu fact urer 's  inst ruct ions .     

grate, ash drawer/tray, wood 

not exceeding 50% of its retail price.

Smoke returns  caused by  environmental 

basket,  fireguard, refractories, 

factors (negative pressure, lack of air, 

metal fire screen, BBQ grill,  3

.  These  warranties  shall  never  be  turbulence, etc.) are not covered by the 

electric fan blower:  

  Being subject 

interpreted as covering workmanship on  present warranty.

to high temperatures, these parts  site.  Don-Bar takes no responsibility for 
may have to be replaced from time to  damages to the building following the 

10.

 

 The warranty does not cover:

time; this is regarded as normal  repair or the replacement of any part 
maintenance.  However, all the 

          

10.1        Broken glass

covered by the warranty. 

original parts shipped with the 

10.2    Damages caused by a 

fireplace are warranted against 

chimney fire;

4.

  No representative, employee or agent 

material or workmanship defects for 

10.3  Shipping damages not 

of Don-Bar is authorized to change or 

1 year following the date of 

reported  on delivery; 

extend the present warranty.

purchase. 

10.4        Faulty installation;
10.5  Damages caused by 

5.

 The warranty is valid only if the 

1.2   Chimney:

  Since the chimney 

abnormal or abusive use.

installation, the operation, and the 

and its components are not 

10.6     

maintenance of the fireplace have been 

manufactured by Don-Bar, please  done in accordance with the fireplace 
refer to the warranty of the chimney  manufacturer written instructions.
manufacturer for any claim  about it.

6.

 Don-Bar takes no responsibility for any 

1.3  Fireplace paint finish:

 The  damage to the fireplace, the chimney or 

fireplace is painted with a high  the building if fireplace repairs done by 
temperature paint that needs to be 

11. Caution: 

Improper operation or lack 

third parties are executed with non 

freshen up from time to time.  

of maintenance can endanger your 

original  parts.  

However, the original finish applied 

safety.

to the  fireplace is warranted for 1 

7.

 Any part that is the object of a claim in 

year following the date of purchase.  

12. Send any communication or claim to 

accordance with the present warranty 

The warranty is limited to the supply 

the following address: 

must by returned to the shop (transport 

of the paint required for repainting  prepaid) with a proof of purchase. All 
the fireplace.

Foyers Don-Bar Fireplaces, inc.

returns must be approved by the 

741, St-Vallier Ouest, Québec,

manufacturer before shipping. 

(Quebec) Canada G6V 3N9
Phone: 418-686-9114
Fax:  418-686-9117
Website:  www.don-bar.com
Email:  [email protected]

        25 YEAR LIMITED WARRANTY                   

LES FOYERS

FIREPLACES

DON-BAR

Содержание CFS SERIES

Страница 1: ...BAR Les foyers DON BAR Fireplaces inc Shop and Showroom 741 St Vallier Ouest Quebec Quebec G1N 1E2 Phone 418 686 9114 Fax 418 686 9117 Website www don bar com Email don bar don bar com CFS SERIES WOO...

Страница 2: ...3 Page 11 Page 18 Page 19 Page 20 PART 5 Warranty Page 1 FIREPLACES This document in its entirety is the intellectual property of Les Foyers Don Bar inc Any unauthorized use will expose its author or...

Страница 3: ...e flap installation 3 Before beginning the 9 2 Humidifier tray installation 9 3 Removable ash shelf 3 1 Choosing the best location 3 1 1 Chimney 3 1 2 Chimney minimum height 3 1 3 Minimum clearances f...

Страница 4: ...INSTALL IN A MOBILE HOME DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE ALWAYS PROVIDE A SOURCE OF FRESH AIR IN THE ROOM AN EXTERIOR FRESH AIR SOURCE MAY BE REQUIRED DO NOT ALTER...

Страница 5: ...easures 2 4 Professional installation For your security enlist the services of a professional fireplace fitter for the installation 2 5 Before your first fire Before lighting your first fire read the...

Страница 6: ...Do not connect this fireplace to a chimney that is connected to another heating device 3 1 2 Chimney minimum height 15 feet 4600 mm for proper operation This length is measured from the floor where t...

Страница 7: ...st never laterally strengthened with a pair of telescopic exceed the number 120 For example maximum roof braces allowed offsets would include two offsets of 30 degree 4 elbows x 30 degrees 120 or an o...

Страница 8: ...of combustible plastics The stove pipe must be a double wall stove pipe approved by ULC UL See pages 9 and 10 for authorized diameters and minimum clearances to combustible walls The clearances vary d...

Страница 9: ...bers Drawing 6 The joints of the floor protection shall be perfectly fitted or filled with grout The floor protection must extend at least 18 460 mm in front of the fireplace door and 8 200 mm on each...

Страница 10: ...7 8 15 31 1 2 48 1 4 24 16 22 3 4 6 7 8 22 3 4 31 1 2 48 1 4 24 16 22 3 4 6 7 8 19 14 692 1226 502 502 527 175 490 200 150 mm 27 1 4 48 1 4 19 3 4 13 20 3 4 6 7 8 26 27 1 4 48 1 4 19 3 4 13 20 3 4 6 7...

Страница 11: ...200 150 mm 36 900 mm Ceiling front wall or combustible material Outlet 8 reducible to 6 Outlet 8 reducible to 6 Outlet 8 reducible to 6 12 305 mm 12 305 mm 12 305 mm Stove pipe minimum clearances 381...

Страница 12: ...uels 3 3 Recommended wood species 9 1 Firescreen 3 4 Green wood 11 Anti smoke flap 9 1 Anti smoke flap installation 4 The fire 4 1 Opening the high efficiency HE smoke damper 13 Humidity and condensat...

Страница 13: ...hot and blazing fire is wanted then open the air intake fully 1 3 Smoke outlet control This sliding valve is a part the of the high efficiency HE deflector system Drawing 22 It is located in the midd...

Страница 14: ...e inadequate chimney height exterior structures harmful to the chimney draft or capable of causing smoke returns an indoor moisture level that is too high and causes ice build up in the flue and reduc...

Страница 15: ...moke rain as long as necessary to allow it to dry Dry damper You will also be able to close gradually wood is easy to identify it is cracked at the ends the air intake control to increase the heating...

Страница 16: ...toring before installation To fireplace safely always keep a poker on hand prevent rusting always store the fireplace and its Heat resistant gloves are also recommended and components in a dry space c...

Страница 17: ...d directly from Don Bar Fireplaces Note the glass panes are not warrantied against breaking Warning Never replace a broken door glass with an ordinary or tempered glass it will shatter and may cause s...

Страница 18: ...even infiltrate the chimney insulation To avoid these problems it is necessary to maintain a 30 35 humidity level inside the house 10 Firescreen installation 11 Anti smoke flap 12 Humidity and conden...

Страница 19: ...per Deflector without the sliding damper Rod and plate assembly for the sliding damper Chimney adaptor Standard Parts Sliding plate for air intake control Hearth plate Anti smoke flap Insert door incl...

Страница 20: ...on t reuse your fireplace firewood until a professional has inspected it A chimney fire Don t let creosote built up in the chimney can overheat the chimney components wrap it Don t burn coniferous con...

Страница 21: ...arrantydoesnotcover time this is regarded as normal repair or the replacement of any part maintenance However all the 10 1 Brokenglass coveredbythewarranty original parts shipped with the 10 2 Damages...

Отзывы: